MétaCan
Menu
Back to cohort
Record W2509705289 · doi:10.1093/rpd/ncw193

SINGLE ANODE TRIPLE GEM TISSUE EQUIVALENT PROPORTIONAL COUNTER AS THE BASIS FOR A PERSONAL NEUTRON DOSIMETER

2016· article· en· W2509705289 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
aboutThe title or abstract carries a Canadian signal from the geographic lexicon.

Bibliographic record

VenueRadiation Protection Dosimetry · 2016
Typearticle
Languageen
FieldPhysics and Astronomy
TopicParticle Detector Development and Performance
Canadian institutionsCanadian Nuclear Laboratories
Fundersnot available
KeywordsDosimeterProportional counterNeutronMonte Carlo methodPhysicsGas electron multiplierEquivalent doseHealth physicsDosimetryOpticsComputational physicsNuclear physicsMaterials scienceNuclear medicineRadiationElectronRadiation protectionMathematicsMedicineDetectorStatistics

Abstract

fetched live from OpenAlex

This paper reports on a tissue-equivalent proportional counter (TEPC) based on a triple gas electron multiplier structure, with a single pad readout, as a basis for a personal neutron dosimeter. Its dosimetric response was studied using the 252Cf neutron source at the Health Physics Generator Facility of the Canadian Nuclear Laboratories. Measured lineal energy spectra were found to be in agreement with numerical simulations performed with Monte Carlo N-Particle eXtended (MCNPX). Both simulations and measurements showed that the mean pathlength of secondary charged particles in the TEPC gas was best represented by the thickness of the drift region of the device. It was determined that the Cauchy Theorem, used to calculate the mean chord length in spherical and cylindrical TEPCs, overestimated the simulated mean chord length by nearly a factor of two. Important operational characteristics of the device were investigated, including gas gain, sensitivity and dosimetric response, as functions of tissue-equivalent gas pressure. This work demonstrates that the proposed design can serve as the basis for a personal neutron dosimeter device, which would satisfy the angular dosimetric response criteria of the personal dosimeter standard IEC61526.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.410
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.261
Teacher spread0.239 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it