Nanoscale Silicon Waveguide Based Thermo-Optic Sensor Using a Compact Mach-Zehnder Interferometer
Bibliographic record
Abstract
A compact Mach-zehnder interferometer with a novel design of directional couplers and a phase shifter has been presented as a thermo-optical sensor. With the aim of reducing device size to micro and nano dimension silicon-on-insulator technology was employed. That allowed miniaturization of device size through the reduction of its cross sectional area to 0.066 µm2 and the radius of curvature of both the arms of the directional coupler and S-bends of the phase shifter to 5 µm and C-bends to 3 µm. These nano size device dimensions made it possible to reduce the coupling gap to 0.2 µm, which resulted in a significant reduction in the coupling length. The device geometry and its performance characteristics were analyzed and optimized using coupled mode analysis and finite difference time domain simulation tools, respectively. The wavelength dependent transmission loss of the device was measured at different temperature to verify and validate its performance characteristics. Tested devices showed a remarkable temperature dependent transmission characteristic offering significant changes in transmission loss band – with as low as 0.45 0C change in substrate temperature. The extinction ratio and the free spectral range of the device were 26 dB and 0.26 nm respectively in the wavelength range of 1549.5 nm – 1550.5 nm. These results imply that the devices presented here can be used as compact and highly sensitive thermal sensors and optical switches.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.001 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".