MétaCan
Menu
Back to cohort
Record W2510870980 · doi:10.1111/pace.12939

Real‐World Assessment of Acute Left Ventricular Lead Implant Success and Complication Rates: Results from the Attain Success Clinical Trial

2016· article· en· W2510870980 on OpenAlexaff
John D. Hummel, Mark A. Coppess, Jeffrey S. Osborn, Raymond Yee, Jeffrey Wing‐Hong Fung, Ralph Augostini, Shelby Li, Douglas Hine, G. André Ng

Bibliographic record

VenuePacing and Clinical Electrophysiology · 2016
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsLondon Health Sciences Centre
Fundersnot available
KeywordsMedicineImplantComplicationCardiac resynchronization therapyFluoroscopySurgeryCoronary sinusAtrial fibrillationProspective cohort studyCatheterLead (geology)CardiologyHeart failureEjection fraction

Abstract

fetched live from OpenAlex

BACKGROUND: Left ventricular lead (LVL) implant success rates have historically ranged between 70.5% and 95.5%. To date, there are few large studies that evaluate LVL implant success utilizing a single family of delivery catheters and leads. The Attain Success study was a prospective nonrandomized multicenter global study with the main objectives of assessing single-system LVL implant success and complication rates. METHODS: Patients undergoing cardiac resynchronization therapy implantation were eligible for enrollment. There was no prespecified level of experience for investigator participation. LVL implant success and complication rates were assessed though 3 months of follow-up. RESULTS: A total of 2,014 patients (69.1 ± 12.0 years, 71% male and 38% atrial fibrillation) were enrolled from 114 centers with a follow-up of 3.5 ± 2.1 months. Coronary sinus cannulation success rate was 96.4% with Attain Family delivery catheters. Implant success rate for Attain Family leads using Attain Family catheters was 94.0%; overall LVL implant success rate was 97.1%. Median procedure time was 4 minutes for cannulation and 9 minutes for LVL placement. Median fluoroscopy time was 17 minutes and median contrast used was 25 cc. There were 55 catheter or LVL-related complications in 53 subjects; the majority were LVL dislodgements (34, 1.7%) and extracardiac stimulation (11, 0.5%). The Kaplan-Meier estimate of the 3-month complication probability was 2.6%. CONCLUSION: This study represents the largest prospective evaluation of LVL implantation to date, revealing a high LVL implant success rate and low complication rate using a single family of leads and delivery catheters.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.091
Threshold uncertainty score0.387

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.059
GPT teacher head0.440
Teacher spread0.380 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2016
Admission routes1
Has abstractyes

Explore more

Same venuePacing and Clinical ElectrophysiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207