MétaCan
Menu
Back to cohort
Record W2510965627 · doi:10.1148/radiol.2016160308

Detection of Steatohepatitis in a Rat Model by Using Spectroscopic Shear-Wave US Elastography

2016· article· en· W2510965627 on OpenAlexafffund
Siavash Kazemirad, Éric Zhang, Bich Nguyen, Paule Bodson‐Clermont, François Destrempes, Dominique Trudel, Guy Cloutier, An Tang

Bibliographic record

VenueRadiology · 2016
Typearticle
Languageen
FieldMedicine
TopicLiver Disease Diagnosis and Treatment
Canadian institutionsCentre Hospitalier de l’Université de Montréal
FundersFonds de Recherche du Québec - SantéFonds de recherche du Québec – Nature et technologiesCanadian Institutes of Health ResearchFonds Québécois de la Recherche sur la Nature et les Technologies
KeywordsSteatohepatitisMedicineSteatosisFibrosisElastographyInternal medicineCirrhosisGastroenterologyPathologyFatty liverUltrasoundRadiologyDisease

Abstract

fetched live from OpenAlex

Purpose To compare low- versus high-frequency ultrasonographic (US) elastography for detection of steatohepatitis in rats by using histopathologic findings as the reference standard. Materials and Methods Between March and September 2014, after receiving approval from the institutional animal care committee, 60 male Sprague-Dawley rats were fed either a standard chow for 4 weeks or a methionine- and choline-deficient diet for 1, 4, 8, or 12 weeks to induce a continuum of steatohepatitis severity. Liver shear stiffness was assessed in vivo by using US elastography at low (40–130-Hz) and high (130–220-Hz) frequencies. Histologic features (steatosis, inflammation, and fibrosis) and modified nonalcoholic steatohepatitis categories were used as reference standards. Definite steatohepatitis was divided into steatohepatitis with fibrosis stage 1 or lower and stage 2 and higher. Analyses included the Kendall τ correlation, multivariable linear regression analyses, Kruskal-Wallis rank sum test, and post hoc Dunn test with Holm correction. Results Correlations between liver shear stiffness and histologic features were higher at high frequencies than at low frequencies (low frequency: 0.08, 0.24, and 0.20 for steatosis, inflammation, and fibrosis, respectively; high frequency: 0.11, 0.35, and 0.50, respectively). The absolute value of multivariable regression coefficients was higher at high frequencies for the presence of steatosis, inflammation grade, and fibrosis stage (low frequency: −0.475, 0.157, and 0.209, respectively; high frequency: −0.893, 0.357, and 0.447, respectively). The model fit was better at high frequencies (adjusted R2 = 0.57) than at low frequencies (adjusted R2 = 0.21). There was a significant difference between steatohepatitis categories at both low and high frequencies (P = .022 and P < .001, respectively). Conclusion Liver shear stiffness measured with US elastography provided better distinction of steatohepatitis categories at high frequencies than at low frequencies. Further, liver shear stiffness decreased with steatosis and increased with inflammation and fibrosis at both low and high frequencies. © RSNA, 2016 Online supplemental material is available for this article.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.133
Threshold uncertainty score0.244

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.250
Teacher spread0.234 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2016
Admission routes2
Has abstractyes

Explore more

Same venueRadiologySame topicLiver Disease Diagnosis and TreatmentFrench-language works237,207