MétaCan
Menu
Back to cohort
Record W2512311268 · doi:10.1088/2057-1976/2/5/055001

A monochromatic x-ray irradiation system for <i>in vitro</i> studies at synchrotron beamlines

2016· article· en· W2512311268 on OpenAlexafffund
M Niestroj, Brian Bewer, Darrell D. Mousseau, D. Chapman, J Chen, J. Hormes

Bibliographic record

VenueBiomedical Physics & Engineering Express · 2016
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsNational Institute for NanotechnologyUniversity of AlbertaUniversity of SaskatchewanCanadian Light Source (Canada)
FundersCanadian Institutes of Health ResearchUniversity of AlbertaCanadian Light Source
KeywordsMonochromatic colorSynchrotronSynchrotron radiationRadiochemistryIrradiationX-rayMedical physicsOpticsNuclear medicineMaterials scienceNuclear engineeringPhysicsChemistryNuclear physicsMedicineEngineering

Abstract

fetched live from OpenAlex

The use of synchrotron light in radiobiological keV x-ray in vitro studies has been accompanied by compromises in culture conditions and sample handling procedures. The presented monochromatic x-ray system bridges the gap between synchrotron science and cell biology by facilitating the irradiation of adherent cells uninterruptedly maintained under cell type-specific conditions throughout the entire experiment. The system for horizontal irradiations consists of a single crystal Laue monochromator, a beam monitor, and a scanning sample stage. As implemented at the BMIT-BM beamline, the system enables homogeneous cell culture irradiations with intense and purely monochromatic x-ray beams (10–30 keV). The first MCF-7 dose-response study demonstrates how the establishment of a stress-minimized experimental procedure leads to accurate and precise in vitro irradiation results. The cell survival as a function of the surface dose is well described by a first-order exponential decay, indicating that the cellular damage induced by 11.9 keV x-rays is comparable to the lethal effects caused by high linear energy transfer particles. The system design opens up the pathway for combined live-cell imaging and monochromatic keV x-ray applications, while the implementation of the system at insertion device beamlines can help to establish novel investigations on the fundamental role of photonactivation agents in an energy regime up to 100 keV.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.015
Threshold uncertainty score0.051

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0150.004

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.262
Teacher spread0.251 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2016
Admission routes2
Has abstractyes

Explore more

Same venueBiomedical Physics & Engineering ExpressSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207