MétaCan
Menu
Back to cohort
Record W2513611368 · doi:10.1136/heartjnl-2016-309707

Transcatheter aortic valve implantation in patients with small aortic annuli using a 20 mm balloon-expanding valve

2016· article· en· W2513611368 on OpenAlexaff
Rishi Puri, Jonathan Byrne, Ralf Müller, Hardy Baumbach, Hélène Eltchaninoff, Simon Redwood, Asim N. Cheema, Christophe Dubois, Leo Ihlberg, Harindra C. Wijeysundera, Alfredo Giuseppe Cerillo, Matthias Götberg, Kaj Erik Klaaborg, Marc Pelletier, Roberto Blanco, Richard Edwards, Caterina Gandolfo, Douglas Muir, Francesco Meucci, Jan-Malte Sinning, Pieter R. Stella, Verena Veulemans, Marko Virtanen, Ander Regueiro, Martin Thoenes, Philippe Pîbarot, Émilie Pelletier-Beaumont, Josep Rodés‐Cabau

Bibliographic record

VenueHeart · 2016
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsHealth Sciences CentreSunnybrook Health Science CentreSt. Michael's HospitalUniversité Laval
Fundersnot available
KeywordsMedicineStenosisAortic valveCardiologyRegurgitation (circulation)BalloonInternal medicineAortic valve stenosisAortic valve replacementProsthesisHeart valveMortality rateSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: While transcatheter aortic valve implantation (TAVI) is established for treating high-operative risk surgical aortic valve replacement candidates, until recently the smallest transcatheter heart valve (THV) measured 23 mm, posing greater risk for annular rupture and THV failure in patients with aortic stenosis (AS) with small aortic annuli (≤20 mm). OBJECTIVES: In the setting of a multicentre registry, we report on the safety, efficacy and early clinical outcomes of the SAPIEN XT 20 mm balloon-expanding THV. RESULTS: Among TAVI 55 recipients (n=30 for native AS, n=25 for a valve-in-valve procedure (V-in-V)), median age and Society of Thoracic Surgeons score were 85 (81 to 87) years and 7.8 (4.7 to 12.4)%, respectively. Mean and minimum annular diameters were 19±1 and 17±2 mm, respectively, in native patients with AS, and 17±1 mm (internal diameter) in V-in-V recipients. Successful device implantation rate was 96%, with no procedural-related death. Overall in-hospital-30-day death, stroke and major bleeding rates were 5%, 2% and 9%, respectively. In native AS TAVI recipients, mean transaortic gradient decreased from 54±20 to 12±5 mm Hg (p<0.001), and from 45±17 to 24±8 mm Hg (p<0.001) in V-in-V recipients. Severe prosthesis-patient mismatch (PPM) rates were 10% and 48% in native AS and V-in-V TAVI recipients, respectively (p=0.03). Post-TAVI, the rate of moderate aortic regurgitation was 7% and 0% in native AS and V-in-V TAVI recipients, respectively. CONCLUSIONS: TAVI with the 20 mm SAPIEN XT THV appears safe and technically feasible, with acceptable short-term clinical outcomes and low rates of severe PPM in those with native AS.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.460

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.304
Teacher spread0.285 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueHeartSame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207