MétaCan
Menu
Back to cohort
Record W2515762702 · doi:10.2967/jnumed.116.174565

Characterization of 3-Dimensional PET Systems for Accurate Quantification of Myocardial Blood Flow

2016· article· en· W2515762702 on OpenAlexafffund
Jennifer M. Renaud, Kathy Yip, Jean Guimond, Mikaël Trottier, Philippe Pîbarot, Éric Turcotte, Conor Maguire, Lucille D. Lalonde, Karen Y. Gulenchyn, Troy Farncombe, Gerald Wisenberg, Jonathan B. Moody, Benjamin C. Lee, Steven C. Port, Timothy G. Turkington, Rob Beanlands, Robert A. deKemp

Bibliographic record

VenueJournal of Nuclear Medicine · 2016
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsSt. Joseph’s Healthcare HamiltonInstitut universitaire de cardiologie et de pneumologie de QuébecUniversity of Alberta HospitalAlberta Hospital EdmontonLawson Health Research InstituteCentre Hospitalier Universitaire de SherbrookeUniversity of Ottawa
FundersUniversity of OttawaLantheus Medical ImagingHeart and Stroke Foundation of Canada
KeywordsCardiac PETImaging phantomBlood flowScannerNuclear medicineCardiac imagingImage qualityPositron emission tomographyPet imagingBiomedical engineeringDynamic rangeMaterials sciencePhysicsMedicineOpticsComputer scienceRadiologyArtificial intelligence

Abstract

fetched live from OpenAlex

Rb-chloride, requires accuracy to be maintained over a wide range of isotope activities and scanner counting rates. We proposed new performance standard measurements to characterize the dynamic range of PET systems for accurate quantitative imaging. METHODS: N-ammonia (1,100-3,000 MBq) was injected into the heart wall insert of an anthropomorphic torso phantom. A decaying isotope scan was obtained over 5 half-lives on 9 different 3D PET/CT systems and 1 3D/2-dimensional PET-only system. Dynamic images (28 × 15 s) were reconstructed using iterative algorithms with all corrections enabled. Dynamic range was defined as the maximum activity in the myocardial wall with less than 10% bias, from which corresponding dead-time, counting rates, and/or injected activity limits were established for each scanner. Scatter correction residual bias was estimated as the maximum cavity blood-to-myocardium activity ratio. Image quality was assessed via the coefficient of variation measuring nonuniformity of the left ventricular myocardium activity distribution. RESULTS: Maximum recommended injected activity/body weight, peak dead-time correction factor, counting rates, and residual scatter bias for accurate cardiac myocardial blood flow imaging were 3-14 MBq/kg, 1.5-4.0, 22-64 Mcps singles and 4-14 Mcps prompt coincidence counting rates, and 2%-10% on the investigated scanners. Nonuniformity of the myocardial activity distribution varied from 3% to 16%. CONCLUSION: Accurate dynamic imaging is possible on the 10 3D PET systems if the maximum injected MBq/kg values are respected to limit peak dead-time losses during the bolus first-pass transit.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.687
Threshold uncertainty score0.185

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.034
GPT teacher head0.310
Teacher spread0.275 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations71
Published2016
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Nuclear MedicineSame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207