MétaCan
Menu
Back to cohort
Record W2516812301 · doi:10.1161/jaha.116.003811

Diagnostic Performance of Treadmill Exercise Cardiac Magnetic Resonance: The Prospective, Multicenter Exercise CMR's Accuracy for Cardiovascular Stress Testing (EXACT) Trial

2016· article· en· W2516812301 on OpenAlexaff
Subha V. Raman, Jennifer A. Dickerson, Wojciech Mazur, Timothy C. Wong, Erik B. Schelbert, James K. Min, Debbie Scandling, Cheryl Bartone, Jason Craft, Paaladinesh Thavendiranathan, Ernest L. Mazzaferri, John W. Arnold, Robert Gilkeson, Orlando P. Simonetti

Bibliographic record

VenueJournal of the American Heart Association · 2016
Typearticle
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsUniversity of Toronto
FundersNational Institutes of Health
KeywordsMedicineMagnetic resonance imagingCardiologyStress testing (software)RadiologyTreadmillNuclear medicineAngiographyInternal medicineRadionuclide angiographyPerfusionHeart failureEjection fraction

Abstract

fetched live from OpenAlex

BACKGROUND: Stress cardiac magnetic resonance (CMR) has typically involved pharmacologic agents. Treadmill CMR has shown utility in single-center studies but has not undergone multicenter evaluation. METHODS AND RESULTS: Patients referred for treadmill stress nuclear imaging (SPECT) were prospectively enrolled across 4 centers. After rest (99m)Tc SPECT, patients underwent resting cine CMR. In-room stress was then performed using an MR-compatible treadmill with continuous 12-lead electrocardiogram monitoring. At peak stress, (99m)Tc was injected, and patients rapidly returned to the MR scanner isocenter for real-time, free-breathing stress cine and perfusion imaging. After recovery, cine and rest perfusion followed by late gadolinium enhancement acquisitions concluded CMR imaging. Stress SPECT was then acquired in adjacent nuclear laboratories. A subset of patients not referred for invasive coronary angiography within 2 weeks of stress underwent coronary computed tomography angiography. Angiographic data available in 94 patients showed sensitivity of 79%, specificity of 99% for exercise CMR with positive predictive value of 92% and negative predictive value of 96%. Agreement between treadmill stress CMR and angiography was strong (κ=0.82), and moderate between SPECT and angiography (κ=0.46) and CMR versus SPECT (κ=0.48). CONCLUSIONS: The multicenter EXACT trial indicates excellent diagnostic value of treadmill stress CMR in typical patients referred for exercise SPECT.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.023
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.059
Threshold uncertainty score0.986

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.023
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.265
Teacher spread0.253 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations64
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueJournal of the American Heart AssociationSame topicCardiac Imaging and DiagnosticsFrench-language works237,207