Three-Dimensional Analysis of Fibular Motion After Fixation of Syndesmotic Injuries With a Screw or Suture-Button Construct
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
BACKGROUND: Suture-button constructs are an alternative to screw fixation for syndesmotic injuries, and proponents advocate that suture-button constructs may allow physiological motion of the syndesmosis. Recent biomechanical data suggest that fibular instability with syndesmotic injuries is greatest in the sagittal plane, but the design of a suture-button construct, being a rope and 2 retention washers, is most effective along the axis of the rope (in the coronal plane). Some studies report that suture-button constructs are able to constrain fibular motion in the coronal plane, but the ability of a tightrope to constrain sagittal fibular motion is unknown. The purpose of this study was to assess fibular motion in response to an external rotation stress test in a syndesmotic injury model after fixation with a screw or suture-button constructs. METHODS: Eleven fresh-frozen cadaver whole legs with intact tibia-fibula articulations were secured to a custom fixture. Fibular motion (coronal, sagittal, and rotational planes) in response to a 6.5-Nm external rotation moment applied to the foot was recorded with fluoroscopy and a high-resolution motion capture system. Measures were taken for the following syndesmotic conditions: intact, complete lateral injury, complete lateral and deltoid injury, repair with a tetracortical 4.0-mm screw, and repair with a suture button construct (Tightrope; Arthrex, Naples, FL) aimed from the lateral fibula to the anterior medial malleolus. RESULTS: The suture-button construct allowed significantly more sagittal plane motion than the syndesmotic screw. Measurements acquired with mortise imaging did not detect differences between the intact, lateral injury, and 2 repair conditions. External rotation of the fibula was significantly increased in both injury conditions and was not restored to intact levels with the screw or the suture-button construct. CONCLUSION: A single suture-button placed from the lateral fibula to the anterior medial malleolus was unable to replicate the motion observed in the intact specimen when subjected to an external rotation stress test and allowed significantly more posterior motion of the fibula than when fixed with a screw in simulated highly unstable injuries. CLINICAL RELEVANCE: Fixation of a syndesmotic injury with a single suture-button construct did not restore physiological fibular motion, which may have implications for postoperative care and clinical outcomes.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.003 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it