MétaCan
Menu
Back to cohort

Estimating oxygen uptake and energy expenditure during treadmill walking by neural network analysis of easy-to-obtain inputs

2016· article· en· W2525602461 on OpenAlexafffund
Thomas Beltrame, Robert Amelard, Rodrigo Villar, Mohammad Javad Shafiee, Alexander Wong, Richard L. Hughson

Bibliographic record

VenueJournal of Applied Physiology · 2016
Typearticle
Languageen
FieldMedicine
TopicCardiovascular and exercise physiology
Canadian institutionsResearch Institute for AgingUniversity of Waterloo
FundersNatural Sciences and Engineering Research Council of CanadaConselho Nacional de Desenvolvimento Científico e TecnológicoAGE-WELL
KeywordsTreadmillEnergy expenditurePhysical medicine and rehabilitationAerobic exercisePopulationArtificial neural networkCardiorespiratory fitnessVO2 maxHeart ratePhysical therapyWork (physics)SimulationPhysical fitnessComputer scienceMedicineMachine learningEngineeringInternal medicine

Abstract

fetched live from OpenAlex

The study of oxygen uptake (V̇o2) dynamics during walking exercise transitions adds valuable information regarding fitness. However, direct V̇o2measurements are not practical for general population under realistic settings. Devices to measure V̇o2are associated with elevated cost, uncomfortable use of a mask, need of trained technicians, and impossibility of long-term data collection. The objective of this study was to predict the V̇o2dynamics from heart rate and inputs from the treadmill ergometer by a novel artificial neural network approach. To accomplish this, 10 healthy young participants performed one incremental and three moderate constant work rate treadmill walking exercises. The speed and grade used for the moderate-intensity protocol was related to 80% of the V̇o2response at the gas exchange threshold estimated during the incremental exercise. The measured V̇o2was used to train an artificial neural network to create an algorithm able to predict the V̇o2based on easy-to-obtain inputs. The dynamics of the V̇o2response during exercise transition were evaluated by exponential modeling. Within each participant, the predicted V̇o2was strongly correlated to the measured V̇o2( = 0.97 ± 0.0) and presented a low bias (~0.2%), enabling the characterization of the V̇o2dynamics during treadmill walking exercise. The proposed algorithm could be incorporated into smart devices and fitness equipment, making them suitable for tracking changes in aerobic fitness and physical health beyond the infrequent monitoring of patients during clinical interventions and rehabilitation programs.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.231
Teacher spread0.224 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations38
Published2016
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Applied PhysiologySame topicCardiovascular and exercise physiologyFrench-language works237,207