MétaCan
Menu
Back to cohort
Record W2530765965 · doi:10.1007/s13361-016-1506-x

An Assessment of the Utility of Tissue Smears in Rapid Cancer Profiling with Desorption Electrospray Ionization Mass Spectrometry (DESI-MS)

2016· article· en· W2530765965 on OpenAlexaff
Michael Woolman, Alessandra Tata, Emma Bluemke, Delaram Dara, Howard J. Ginsberg, Arash Zarrine‐Afsar

Bibliographic record

VenueJournal of the American Society for Mass Spectrometry · 2016
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsUniversity of TorontoSt. Michael's HospitalUniversity Health Network
Fundersnot available
KeywordsMass spectrometryChemistryReproducibilityBreast cancerBreast tissueAnalytical Chemistry (journal)PathologyCancerBiomedical engineeringChromatographyMedicine

Abstract

fetched live from OpenAlex

Mass spectrometry imaging with desorption electrospray ionization mass spectrometry (DESI-MS) is used to characterize cancer from ex vivo slices of tissues. The process is time-consuming. The use of tissue smears for DESI-MS analysis has been proposed as it eliminates the time required to snap-freeze and section the tissue. To assess the utility of tissue smears for rapid cancer characterization, principal component analysis (PCA) was performed to evaluate the concordance between DESI-MS profiles of breast cancer from tissue slices and smears prepared on various surfaces. PCA suggested no statistical discrimination between DESI-MS profiles of tissue sections and tissue smears prepared on glass, polytetrafluoroethylene (PTFE), and porous PTFE. However, the abundances of cancer biomarker ions varied between sections and smears, with DESI-MS analysis of tissue sections yielding higher ion abundances of cancer biomarkers compared with smears. Coefficient of variance (CV) analysis suggests DESI-MS profiles from tissue smears are as reproducible as the ones from tissue sections. The limit of detection with smear samples from single pixel analysis is comparable to tissue sections that average the signal from a tissue area of 0.01 mm 2 . The smears prepared on the PTFE surface possessed a higher degree of homogeneity compared with the smears prepared on the glass surface. This allowed single MS scans (~1 s) from random positions across the surface of the smear to be used in rapid cancer typing with good reproducibility, providing pathologic information for cancer typing at speeds suitable for clinical utility.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.018

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.004
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0000.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.315
Teacher spread0.303 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations29
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueJournal of the American Society for Mass SpectrometrySame topicMass Spectrometry Techniques and ApplicationsFrench-language works237,207