MétaCan
Menu
Back to cohort
Record W2533537845 · doi:10.1109/embc.2016.7591416

Low-frequency ultrasound radiosensitization and therapy response monitoring of tumors: An in vivo study

2016· article· en· W2533537845 on OpenAlexafffund
Ali Sadeghi‐Naini, Martin Stanisz, Hadi Tadayyon, Jaswinder Taank, Gregory J. Czarnota

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicUltrasound and Hyperthermia Applications
Canadian institutionsSunnybrook Health Science CentreUniversity of Toronto
FundersCanadian Institutes of Health Research
KeywordsUltrasoundMicrobubblesRadiation therapyIn vivoBiomarkerImmunohistochemistryReceiver operating characteristicMedicineFibrosarcomaProgrammed cell deathLinear discriminant analysisPathologyBiomedical engineeringRadiologyBiologyComputer scienceInternal medicineApoptosis

Abstract

fetched live from OpenAlex

A new framework has been introduced in this paper for tumor radiosensitization and therapy response monitoring using low-frequency ultrasound. Human fibrosarcoma xenografts grown in severe combined immunodeficiency (SCID) mice (n = 108) were treated using ultrasound-stimulated microbubbles at various concentration and exposed to different doses of radiation. Low-frequency ultrasound radiofrequency (RF) data were acquired from tumors prior to and at different times after treatment. Quantitative ultrasound (QUS) techniques were applied to generate spectral parametric maps of tumors. Textural analysis were performed to quantify spatial heterogeneities within QUS parametric maps. A hybrid model was developed using multiple regression analysis to predict extent of histological tumor cell death non-invasively based on QUS spectral and textural biomarkers. Results of immunohistochemistry on excised tumor sections demonstrated increases in cell death with higher concentration of microbubbles and radiation dose. Quantitative ultrasound results indicated changes that paralleled increases in histological cell death. Specifically, the hybrid QUS biomarker demonstrated a good correlation with extent of tumor cell death observed from immunohistochemistry. A linear discriminant analysis applied in conjunction with the receiver operating characteristic (ROC) curve analysis indicated that the hybrid QUS biomarker can classify tumor cell death fractions with an area under the curve of 91.2. The results obtained in this research suggest that low-frequency ultrasound can concurrently be used to enhance radiation therapy and evaluate tumor response to treatment.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.236
Teacher spread0.224 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2016
Admission routes2
Has abstractyes

Explore more

Same topicUltrasound and Hyperthermia ApplicationsFrench-language works237,207