MétaCan
Menu
Back to cohort
Record W2533556791 · doi:10.1109/epc.2007.4520388

Improved Power Quality Based Controller for a 3-Phase 4-Wire Isolated Wind Energy System

2007· article· en· W2533556791 on OpenAlexaff
Bhim Singh, Gaurav Kumar Kasal, Ambrish Chandra, Kamal-Al-Haddad

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicWind Turbine Control Systems
Canadian institutionsÉcole de Technologie SupérieureUniversité du Québec à Montréal
Fundersnot available
KeywordsControl theory (sociology)Wind powerInsulated-gate bipolar transistorController (irrigation)Voltage sourceCapacitorThree-phasePower factorEngineeringVoltageInduction generatorElectrical engineeringComputer science

Abstract

fetched live from OpenAlex

This paper deals with the regulation of voltage and frequency of an isolated wind energy conversion system (IWECS) based on a capacitor excited asynchronous generator and feeding 3-phase 4-wire loads. The proposed controller consists of an IGBT (Insulted Gate Bipolar Junction Transistor) based 4-leg voltage source converter (VSC) and a battery at its DC link. A bank of excitation capacitor with neutral and fourth leg of the proposed controller provides the neutral terminal for the loads. The complete electromechanical system is modeled and simulated in MATLAB using Simulink and PSB (Power System Blockset) toolboxes. The simulated results are presented to demonstrate the capability of the proposed controller as a voltage and frequency regulator, a harmonic eliminator, a load balancer, and a neutral current compensator for different electrical (consumer loads variation) and mechanical (wind speed variation) dynamic conditions in an isolated wind energy conversion system.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.247
Teacher spread0.238 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2007
Admission routes1
Has abstractyes

Explore more

Same topicWind Turbine Control SystemsFrench-language works237,207