MétaCan
Menu
Back to cohort

Impact of Left Ventricular to Mitral Valve Ring Mismatch on Recurrent Ischemic Mitral Regurgitation After Ring Annuloplasty

2016· article· en· W2534973406 on OpenAlexfundno aff
Romain Capoulade, Xin Zeng, Jessica Overbey, Gorav Ailawadi, John H. Alexander, Deborah D. Ascheim, Michael E. Bowdish, Annetine C. Gelijns, Paul Grayburn, Irving L. Kron, Robert A. Levine, Michael J. Mack, Serguei Melnitchouk, Robert E. Michler, John C. Mullen, Patrick T. O’Gara, Michael K. Parides, Peter K. Smith, Pierre Voisine, Judy Hung

Bibliographic record

VenueCirculation · 2016
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsnot available
FundersNational Heart, Lung, and Blood InstituteCanadian Institutes of Health ResearchNational Institutes of Health
KeywordsMedicineCardiologyEjection fractionInternal medicineRing sizeMitral valve repairConfidence intervalMitral regurgitationMitral valveRing (chemistry)Heart failure

Abstract

fetched live from OpenAlex

BACKGROUND: In ischemic mitral regurgitation (IMR), ring annuloplasty is associated with a significant rate of recurrent MR. Ring size is based on intertrigonal distance without consideration of left ventricular (LV) size. However, LV size is an important determinant of mitral valve (MV) leaflet tethering before and after repair. We aimed to determine whether LV-MV ring mismatch (mismatch of LV size relative to ring size) is associated with recurrent MR in patients with IMR after restrictive ring annuloplasty. METHODS: Patients with moderate or severe IMR from the 2 Cardiothoracic Surgical Trials Network IMR trials who received MV repair were examined at 1 year after surgery. Baseline LV size was assessed by LV end-diastolic dimension and LV end-systolic dimension (LVESd). LV-MV ring mismatch was calculated as the ratio of LV to ring size (LV end-diastolic dimension/ring size and LVESd/ring size). RESULTS: At 1 year after ring annuloplasty, 45 of 214 patients with MV repair (21%) had moderate or greater MR. In univariable logistic regression analysis, larger LVESd (P=0.02) and LVESd/ring size (P=0.007) were associated with recurrent MR. In multivariable models adjusted for age, sex, baseline LV ejection fraction, and severe IMR, only LVESd/ring size (odd ratio per 0.5 increase, 2.20; 95% confidence interval, 1.05-4.62; P=0.038) remained significantly associated with 1-year MR recurrence. CONCLUSIONS: LV-MV ring size mismatch is associated with increased risk of MR recurrence. This finding may be helpful in guiding choice of ring size to prevent recurrent MR in patients undergoing MV repair and in identifying patients who may benefit from MV repair with additional subvalvular intervention or MV replacement rather than repair alone. CLINICAL TRIAL REGISTRATION: URL:http://clinicaltrials.gov. Unique identifiers: NCT00806988 and NCT00807040.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.006
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.319
Teacher spread0.307 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations62
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueCirculationSame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207