Efficient compressive sensing of ECG segments based on machine learning for QRS-based arrhythmia detection
Bibliographic record
Abstract
A novel method for efficient telemonitoring of arrhythmia based on using QRS complexes is proposed. Two features, namely, sum of absolute differences (SAD) and maximum of absolute differences (MAD) are efficiently computed for each ECG segment in the bio-sensor. The computed features can be transmitted from the bio-sensor using wireless channel, and they can be used in the receiver for determining the absence of QRS complex in the segment. By avoiding computationally expensive signal reconstruction for the ECG segments without QRS complex, it is shown, using simulation results, that computation time can be reduced by approximately 7.4% for long-term telemonitoring of QRS-based arrhythmia. Detection of the absence of QRS complex can be carried out in around 7 milliseconds in a standard laptop computer with 2.2GHz processor and 8GB RAM.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".