MétaCan
Menu
Back to cohort
Record W2541745727 · doi:10.1519/jsc.0000000000001688

A Single Session of Low-Volume High-Intensity Interval Exercise Reduces Ambulatory Blood Pressure in Normotensive Men

2016· article· en· W2541745727 on OpenAlexaff
Teresa Cristina Batista Dantas, Luiz Fernando Farias-Junior, Danniel Thiago Frazão, Paulo H.M. Silva, Altieres Elias de Sousa, Ingrid Bezerra Barbosa Costa, Raphael Mendes Ritti‐Dias, C. L. M. Forjaz, Todd A. Duhamel, Eduardo Caldas Costa

Bibliographic record

VenueThe Journal of Strength and Conditioning Research · 2016
Typearticle
Languageen
FieldMedicine
TopicCardiovascular and exercise physiology
Canadian institutionsUniversity of ManitobaResearch ManitobaSt. Boniface Hospital
Fundersnot available
KeywordsSession (web analytics)AmbulatoryAmbulatory blood pressureMedicineHigh-intensity interval trainingCardiologyIntensity (physics)Blood pressureInternal medicineVolume (thermodynamics)Physical therapyComputer sciencePhysics

Abstract

fetched live from OpenAlex

Dantas, TCB, Farias Junior, LF, Frazão, DT, Silva, PHM, Sousa Junior, AE, Costa, IBB, Ritti-Dias, RM, Forjaz, CLM, Duhamel, TA, and Costa, EC. A single session of low-volume high-intensity interval exercise reduces ambulatory blood pressure in normotensive men. J Strength Cond Res 31(8): 2263-2269, 2017-The magnitude and duration of postexercise hypotension (PEH) may provide valuable information on the efficacy of an exercise approach to blood pressure (BP) control. We investigated the acute effect of a time-efficient high-intensity interval exercise (HIIE) on ambulatory BP. Twenty-one normotensive men (23.6 ± 3.6 years) completed 2 experimental sessions in a randomized order: (a) control (no exercise) and (b) low-volume HIIE: 10 × 1 minute at 100% of maximal treadmill velocity interspersed with 1 minute of recovery. After each experimental session, an ambulatory BP monitoring was initiated. Paired sample t-test was used to compare BP averages for awake, asleep, and 20-hour periods between the control and the low-volume HIIE sessions. A 2-way repeated measures analysis of variance was used to analyze hourly BP after both experimental sessions. Blood pressure averages during the awake (systolic: 118 ± 6 vs. 122 ± 6 mm Hg; diastolic: 65 ± 7 vs. 67 ± 7 mm Hg) and 20-hour (systolic: 115 ± 7 vs. 118 ± 6 mm Hg; diastolic: 62 ± 7 vs. 64 ± 7 mm Hg) periods were lower after the low-volume HIIE compared with the control (p ≤ 0.05). Systolic and diastolic PEH presented medium (Cohen's d = 0.50-0.67) and small (Cohen's d = 0.29) effect sizes, respectively. Systolic PEH occurred in a greater magnitude during the first 5 hours (3-5 mm Hg). No changes were found in asleep BP (p > 0.05). In conclusion, a single session of low-volume HIIE reduced ambulatory BP in normotensive men. The PEH occurred mainly in systolic BP during the first 5 hours postexercise.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Non-randomized trial · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.290
Teacher spread0.271 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNon-randomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations21
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueThe Journal of Strength and Conditioning ResearchSame topicCardiovascular and exercise physiologyFrench-language works237,207