MétaCan
Menu
Back to cohort
Record W2545421147 · doi:10.1109/cmd.2012.6416467

Effect of long-term aging test under DC voltage on Roebel bars

2012· article· en· W2545421147 on OpenAlexaff
M. Bélec, C. Guddemi, Charles Millet

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldMaterials Science
TopicHigh voltage insulation and dielectric phenomena
Canadian institutionsHydro-Québec
Fundersnot available
KeywordsVoltageElectrical engineeringStatorMaterials scienceHigh voltageAccelerated agingComposite materialPartial dischargeBreakdown voltageEngineering

Abstract

fetched live from OpenAlex

Measurement of the charging and discharging current of stator winding insulation under DC high voltage is one of the tests used in assessing the condition of rotating machines. Since the DC high voltage may be applied for a relatively long period of time during the charging of the winding, the value of the applied voltage can be a matter of concern, and no aging of the insulation under test should occur while the condition assessment is performed. Previous experimentation compared the aging effect of AC and DC high voltage on the groundwall insulation of 13.8-kV Roebel bars. A Voltage Endurance Test (VET) was performed on 12 spare bars for this purpose. Half of the test specimens were subjected to a voltage of 35 kVac, and failures occurred on all bars in less than 150 h. A ratio of 1.7 was used between the direct voltage and power frequency voltage (rms) for these tests. The other half of the specimens were then tested at a voltage of 59.5 kVdc and no failure occurred after more than 2000 h. It was later decided to perform an AC voltage endurance test on bars previously tested under DC voltage, to try to evaluate the effect of DC VET on the integrity of the insulation. Another aspect of the aging process that was evaluated during these experiments was the effect of corona partial discharge activity at the junction of semi-conducting (S/C) and stress-grading coatings. Another six bars of the same production were modified in order to generate sustained corona PD activity to try to establish the associated risk. This paper presents the results of comparative VETs between AC and DC voltages performed on the epoxy-mica based insulation of hydro-generator Roebel bars, as well as results of AC VET performed on six bars previously subjected to a long-term DC VET and the effect of corona activity on the integrity of the insulation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.276
Teacher spread0.263 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2012
Admission routes1
Has abstractyes

Explore more

Same topicHigh voltage insulation and dielectric phenomenaFrench-language works237,207