Biomechanical optimization of the angle and position for surgical implantation of a straight short stem hip implant

2016· article· en· W2547285218 on OpenAlexaff
Gillian E. Cook, Saeid Samiezadeh, Zachary Morison, Mina S.R. Aziz, Habiba Bougherara, Radovan Zdero, Emil H. Schemitsch

Bibliographic record

VenueMedical Engineering & Physics · 2016
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsVictoria HospitalWestern UniversitySt. Michael's HospitalUniversity of British ColumbiaToronto Metropolitan UniversityUniversity of Toronto
Fundersnot available
KeywordsValgusFemurImplantOrthodonticsGait cycleGaitOrientation (vector space)Range of motionBiomechanicsMedicineAnatomySurgeryKinematicsPhysical medicine and rehabilitationMathematicsGeometryPhysics

Abstract

fetched live from OpenAlex

Conservative hip implants preserve healthy bone for revision surgeries and improve physiological loading; however, they have little supporting biomechanical data with respect to their 3D orientation during implantation. This study endeavored to determine the optimal 3D orientation of a straight short stem hip implant within the proximal femur that would yield a stress distribution most similar to an intact femur. Synthetic femurs were implanted with a stem in one of seven maximum angles or positions and axially loaded, with resultant strain values used to validate a finite element model. Design of experiments was used to analyze the range of potential implant orientations under three gait cycle loading conditions. A global optimal orientation of 9.14° valgus, 2.49° anteversion, 0.48mm posterior position, and 0.23mm inferior position was found to yield stress distributions most similar to the intact femur across the gait cycle range. In general, it was determined that the valgus orientation was optimal throughout the gait cycle, consistently exhibiting a stress distribution more similar to that of the intact femur. Minimal levels of anterior/posterior and inferior positioning were seen to be beneficial in achieving more physiological stresses in specific regions of interest within the proximal femur, while the anteverted orientation was only beneficial in loading under flexion. Overall, orthopaedic surgeons should aim to implant straight short stem hip implants in valgus up to 10°, with an otherwise neutral position and version, unless some degree of deviation would be beneficial for a patient-specific reason. This work has implications for the best surgical placement of straight short stem hip implants to yield maximal biomechanical stability.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.789
Threshold uncertainty score0.189

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.234
Teacher spread0.224 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueMedical Engineering & PhysicsSame topicOrthopaedic implants and arthroplastyFrench-language works237,207