MétaCan
Menu
Back to cohort
Record W2549048760 · doi:10.1109/nssmic.2013.6829318

Performance evaluation of SensL SiPM arrays for high-resolution PET

2013· article· en· W2549048760 on OpenAlexaff
Jonathan D. Thiessen, Carl Jackson, Kevin O’Neill, D. Bishop, Piotr Kozłowski, F. Retière, Ehsan Shams, Greg Stortz, Christopher J. Thompson, Andrew L. Goertzen

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldPhysics and Astronomy
TopicRadiation Detection and Scintillator Technologies
Canadian institutionsMontreal Neurological Institute and HospitalMcGill UniversityUniversity of British ColumbiaTRIUMFUniversity of Manitoba
Fundersnot available
KeywordsSilicon photomultiplierBreakdown voltagePhysicsDark currentDark matterAnalytical Chemistry (journal)OptoelectronicsTopology (electrical circuits)Materials scienceVoltageElectrical engineeringParticle physicsDetectorChemistryOpticsScintillatorEngineeringPhotodetector

Abstract

fetched live from OpenAlex

Silicon photomultipliers (SiPMs) have high gain, excellent timing performance, and are well suited to PET/MRI applications due, in part, to their MR-compatibility and small form factor. Within the constraints of a resistor-based multiplexing circuit, it is useful to evaluate the four generations of SiPM arrays manufactured by SensL: the SPMArray4, ArraySL-4, ArraySM-4, and ArraySB-4. Breakdown voltage and dark current were measured as a function of temperature in two each of the four generations of SensL SiPM arrays. Flood histograms were created with a <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">68</sup> Ge-irradiated 9×9 LYSO crystal array at temperatures of 5 °C to 45 °C in 5 °C increments and overvoltages of 2 to 4 V in 0.5 V increments. Measurements of dark current vs. bias voltage increased as temperature increased, with a corresponding increase in the breakdown voltage, V <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">b</sub> . The temperature dependence of V <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">b</sub> is similar between all four generations of SiPM arrays with slopes ranging from 17.0 to 23.8 mV/°C. Notably, the ArraySB-4 has lower values for the breakdown voltage, with V <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">b</sub> = 24 V at 0 °C. Mean energy resolution for individual LYSO crystals showed improvements in each successive generation. The average energy resolution of the ArraySB-4 was 11.9% after correcting for non-linearity in the SiPM pixels. The linearity of the SensL SiPM arrays as a function of temperature and breakdown voltage makes them a suitable choice for a high-resolution, small animal PET/MRI system. Based on its improved resolvability and energy resolution, lower sensitivity to temperature and higher PDE, the ArraySB-4 will be used in our PET system.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.822
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.252
Teacher spread0.232 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations22
Published2013
Admission routes1
Has abstractyes

Explore more

Same topicRadiation Detection and Scintillator TechnologiesFrench-language works237,207