MétaCan
Menu
Back to cohort
Record W2549281934 · doi:10.1155/2016/3762484

<i>In Vivo</i>Remodeling of Fibroblast-Derived Vascular Scaffolds Implanted for 6 Months in Rats

2016· article· en· W2549281934 on OpenAlexafffund
Maxime Y. Tondreau, Véronique Laterreur, Karine Vallières, Robert Gauvin, Jean‐Michel Bourget, Catherine Tremblay, Dan Lacroix, Lucie Germain, Jean Ruel, François A. Auger

Bibliographic record

VenueBioMed Research International · 2016
Typearticle
Languageen
FieldMaterials Science
TopicElectrospun Nanofibers in Biomedical Applications
Canadian institutionsRegroupement Québécois sur les Matériaux de PointeUniversité LavalCentre hospitalier de l'Université Laval
FundersFonds de Recherche du Québec - SantéNatural Sciences and Engineering Research Council of CanadaFonds de recherche du Québec – Nature et technologiesCanadian Institutes of Health ResearchUniversité Laval
KeywordsDecellularizationBiomedical engineeringScaffoldExtracellular matrixIn vivoTissue engineeringFibroblastBlood vesselAnatomyMaterials sciencePathologyChemistryMedicineCell biologyIn vitroBiologyInternal medicine

Abstract

fetched live from OpenAlex

There is a clinical need for tissue-engineered small-diameter (<6 mm) vascular grafts since clinical applications are halted by the limited suitability of autologous or synthetic grafts. This study uses the self-assembly approach to produce a fibroblast-derived decellularized vascular scaffold (FDVS) that can be available off-the-shelf. Briefly, extracellular matrix scaffolds were produced using human dermal fibroblasts sheets rolled around a mandrel, maintained in culture to allow for the formation of cohesive and three-dimensional tubular constructs, and decellularized by immersion in deionized water. The FDVSs were implanted as an aortic interpositional graft in six Sprague-Dawley rats for 6 months. Five out of the six implants were still patent 6 months after the surgery. Histological analysis showed the infiltration of cells on both abluminal and luminal sides, and immunofluorescence analysis suggested the formation of neomedia comprised of smooth muscle cells and lined underneath with an endothelium. Furthermore, to verify the feasibility of producing tissue-engineered blood vessels of clinically relevant length and diameter, scaffolds with a 4.6 mm inner diameter and 17 cm in length were fabricated with success and stored for an extended period of time, while maintaining suitable properties following the storage period. This novel demonstration of the potential of the FDVS could accelerate the clinical availability of tissue-engineered blood vessels and warrants further preclinical studies.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.018
Threshold uncertainty score0.590

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.036
GPT teacher head0.361
Teacher spread0.325 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2016
Admission routes2
Has abstractyes

Explore more

Same venueBioMed Research InternationalSame topicElectrospun Nanofibers in Biomedical ApplicationsFrench-language works237,207