Significant Increase in Reporting of Transfusion Reactions with the Implementation of an Electronic Reporting System

2015· article· en· W2550933501 on OpenAlexaffabout
Rosanne St. Bernard, Matthew Yan, Shuoyan Ning, Alioska Escorcia, Jacob Pendergrast, Christine Cserti‐Gazdewich

Bibliographic record

VenueBlood · 2015
Typearticle
Languageen
FieldBusiness, Management and Accounting
TopicBlood donation and transfusion practices
Canadian institutionsUniversity Health NetworkUniversity of TorontoWestern University
Fundersnot available
KeywordsMedicineMedical emergencyTransfusion medicineEmergency medicineDocumentationBlood transfusionSurgeryComputer science

Abstract

fetched live from OpenAlex

Abstract Introduction In robust hospital transfusion services, transfusion reaction reporting triggers a structured response to the assessment, diagnosis, and clinical management of the individual. At a population level, the feedback loop of hemovigilance permits the perception of signals applicable to donors, material production, patterns of use, infusion care, and recipient vulnerabilities. Transfusion reaction reporting therefore aims to improve the quality of patient care and safety in transfusion, which remains one of the most commonly performed procedures in medicine today. Large variations between passive/retrospective or active/prospective systems imply underreporting. Reasons for this may lie in unawareness of, nihilism on, or obstacles to this duty. In 2009, our center transitioned from a paper-based to an electronic reporting system (ERS) for suspected patient reaction events (PREs). This study sought to determine the impact of this change on PRE reporting rates. Methods This study was conducted in Toronto, Canada at the University Health Network, a 4-site, 767-bed, ternary care hospital with high transfusion activity (2014: 60,000 component and 30,000 derivative dispensations). In 05/2009, hardcopy mountsheets for transfusion labels were revised to provide space for recording corresponding vital signs, with instructions on PRE reporting. Medical director PRE review followed with event documentation in a transfusion laboratory database (recording imputability, reaction type, severity, and implicated product(s)). An Acute Transfusion Reaction policy was also developed to protocolize and further streamline the approach to various reactions, but was not implemented across all sites until 11/2009. At this time, electronic PRE reporting went live in the existing electronic medical record, with medical director review hereafter culminating in uploaded case conclusions. Technical tutorials on healthcare worker reporting spanned several months before implementation, without emphasizing the theory or evidence-based value of hemovigilance. The quantity and characteristics of reactions pre-/post-ERS implementation were compared. Results Prior to the ERS option (5/2009-11/2009), the reported PRE rate was 0.26/day. Subsequent to launch (11/2009-12/2009), the reported PRE rate was 0.66/day, representing a 2.54 fold increase (p<0.05) (Figure 1). This nearly-trebled rate has been sustained throughout subsequent years: 01/2010-12/2010: 0.88/day; 01/2011-12/2011: 0.87/day; 01/2012-12/2012: 0.87/day; 01/2013-12/2013: 0.88/day; 01/2014-12/2014: 0.93/day. The distribution of PRE conclusions pre-ERS was: febrile non-hemolytic transfusion reaction (FNHTR) 40%; unrelated to transfusion (UTR) 34%; allergic transfusion reaction (ATR) 7.3%; query bacterial contamination (BaCON) 4.9%; transfusion related acute lung injury (TRALI) 3.6% and transfusion related circulatory overload (TACO) 2.4%. The distribution of PRE conclusions after ERS (11/2009-12/2014) was: ATR 28.8%; UTR 28.7%; FNHTR 19.9%; TACO 8.6%; transfusion associated dyspnea 4.7%; pain 3.2%; query BaCON 2.3% and TRALI 1.7%. Conclusions Our data demonstrate that PRE reporting significantly increased and was sustained after the implementation of an ERS. This finding suggests that despite a dearth of strategies to address underreporting, the solution may lie in removing disincentives while facilitating action in familiar practice platforms. Two other studies investigated the implementation of an ERS for transfusion reaction reporting (Fujihara H. et al. 2015; Yeh, S et al. 2011), with one confounded by a significant increase in transfusion rates in the post-ERS period. In contrast, our denominator of blood utilization has been stable or decreasing across sites over the last five years, with 3% of product recipients nevertheless experiencing a PRE. Despite the significant increase in reported PREs, we did not see an increase in UTRs (34% vs 25%) to account for the difference, arguing against "junk inflations," while rather suggesting that reporter suspicions generally concur with specialist conclusions on transfusion imputability. Given the importance of accurate transfusion reaction reporting for patient safety, we suggest that this strategy be considered by other centers to improve reporting activity with its potential downstream benefits. Disclosures No relevant conflicts of interest to declare.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.219
Threshold uncertainty score0.991

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0040.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.027
GPT teacher head0.281
Teacher spread0.254 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueBloodSame topicBlood donation and transfusion practicesFrench-language works237,207