MétaCan
Menu
Back to cohort
Record W2554984574 · doi:10.1097/aog.0000000000001776

Imaging for Polyps and Leiomyomas in Women With Abnormal Uterine Bleeding

2016· review· en· W2554984574 on OpenAlexaff
Sarah Maheux‐Lacroix, Fiona Li, Philippe Y. Laberge, Jason Abbott

Bibliographic record

VenueObstetrics and Gynecology · 2016
Typereview
Languageen
FieldMedicine
TopicGynecological conditions and treatments
Canadian institutionsUniversité Laval
Fundersnot available
KeywordsMedicineHysteroscopyProspective cohort studyHysterectomyEndometrial PolypUltrasoundRadiologyLeiomyomaSalineGynecologySurgeryInternal medicine

Abstract

fetched live from OpenAlex

OBJECTIVE: To evaluate the accuracy of saline infusion sonohysterography in comparison with transvaginal ultrasonography for diagnosing polyps and submucosal leiomyomas in women with abnormal uterine bleeding. DATA SOURCES: We searched the databases MEDLINE, EMBASE, CENTRAL, and ClinicalTrials.gov as well as citations and reference lists to the end of November 2015. METHODS OF STUDY SELECTION: Two authors screened 5,347 citations for eligibility. We included randomized controlled trials or prospective cohort studies published in English, assessing the accuracy of saline infusion sonohysterography and transvaginal ultrasonography for diagnosing polyps and submucosal leiomyomas in women with abnormal uterine bleeding. We considered studies using histopathologic specimens obtained at either hysteroscopy or hysterectomy as criterion standard. TABULATION, INTEGRATION, AND RESULTS: Twenty-five studies were eligible. Two authors extracted data and assessed the quality of included studies. Bivariate random-effects models were used to compare the different tests and evaluate sources of heterogeneity. Saline infusion sonohysterography was superior to transvaginal ultrasonography with pooled sensitivity and specificity of 0.92 and 0.89 compared with 0.64 and 0.90, respectively (P<.001). Transvaginal ultrasound sensitivity for diagnosing polyps was particularly low (0.51). Saline infusion sonohysterography was also compared with hysteroscopy in seven studies and had similar sensitivity but inferior specificity (0.93 and 0.83 compared with 0.95 and 0.90, respectively, P=.007). All three procedures were well-tolerated by women. Saline infusion sonohysterography was successfully completed in 95% of women. Technical variations such as the use of balloon catheters were not found to affect diagnostic accuracy. CONCLUSION: Transvaginal ultrasonography lacks sensitivity to be used alone to exclude the presence of polyps and leiomyomas in women with abnormal uterine bleeding. Although less specific than hysteroscopy, saline infusion sonohysterography offers a similar detection rate and permits concomitant visualization of the ovaries and myometrium. Cost, convenience, and tolerability of different imaging techniques require further evaluation. SYSTEMATIC REVIEW REGISTRATION: PROSPERO International prospective register of systematic reviews, http://www.crd.york.ac.uk/PROSPERO, CRD42016034005.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.993
Threshold uncertainty score0.718

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.318
Teacher spread0.289 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations30
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueObstetrics and GynecologySame topicGynecological conditions and treatmentsFrench-language works237,207