MétaCan
Menu
Back to cohort
Record W2556831728 · doi:10.1021/acs.analchem.6b03160

Development of a Biocompatible In-Tube Solid-Phase Microextraction Device: A Sensitive Approach for Direct Analysis of Single Drops of Complex Matrixes

2016· article· en· W2556831728 on OpenAlexafffund
Hamed Piri‐Moghadam, Sofia Lendor, Janusz Pawliszyn

Bibliographic record

VenueAnalytical Chemistry · 2016
Typearticle
Languageen
FieldChemistry
TopicAnalytical chemistry methods development
Canadian institutionsUniversity of Waterloo
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsChemistryBiocompatible materialSolid-phase microextractionTube (container)ChromatographyPhase (matter)NanotechnologyBiomedical engineeringMass spectrometryGas chromatography–mass spectrometryOrganic chemistryComposite material

Abstract

fetched live from OpenAlex

The aim of the current study is to develop a sensitive solid-phase microextraction (SPME) device for direct and rapid analysis of untreated complex matrixes (i.e., single drop of the samples, V ≤ 2 μL). A thin layer of a biocompatible nanostructured polypyrrole (PPy) was electrochemically deposited inside a medical grade spinal needle, minimizing the matrix effect. Microsampling was facilitated by loading the sample inside the in-tube SPME device (withdraw of sample via plunger), where extraction was performed under static conditions. Two strategies were used for analysis of the compounds including offline desorption and running the extract to the liquid chromatograph-tandem mass spectrometer (LC-MS/MS) or direct coupling of the in-tube SPME device to the MS. Given the high surface-area-to-volume ratio of the coating, a short equilibrium time (i.e., t ≤ 2 min) was obtained. The whole analytical procedure (i.e., extraction, rinsing, desorption, and LC-MS/MS analysis) was performed within 10 min by LC-MS/MS, and 3 min by in-tube-MS/MS. Possible matrix effects for the prepared device were evaluated in whole blood samples at three levels of concentration, and encouraging results were achieved in the range of 83-120%. The obtained results, no matrix effect, are attributed to the smooth surface and small pore size of the biocompatible PPy coating, which was prepared in the presence of cetyltrimethylammonium bromide (CTAB) surfactant. The in-tube SPME device was shown to be very sensitive, with high total recoveries obtained for all compounds in phosphate-buffered saline (PBS) and urine samples owing to the large volume and capacity of the coating. Subnanogram per milliliter levels of detection were achieved for urine samples, and low nanogram per milliliter levels were found in whole blood samples for all studied compounds with a high protein binding index. Rapid analysis of whole blood samples was achieved without need of any pretreatment or manipulation of sample, revealing the developed in-tube SPME device as an ideal probe for forensic application, drug monitoring, and point-of care-diagnosis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.027
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.066
GPT teacher head0.370
Teacher spread0.304 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations43
Published2016
Admission routes2
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicAnalytical chemistry methods developmentFrench-language works237,207