MétaCan
Menu
Back to cohort
Record W2559120492 · doi:10.1021/acs.est.6b03418

A Novel Technique for Determining the Adsorption Capacity and Breakthrough Time of Adsorbents Using a Noncontact High-Resolution Microwave Resonator Sensor

2016· article· en· W2559120492 on OpenAlexafffund
Mohammadreza Fayaz, Mohammad H. Zarifi, Mohammad Abdolrazzaghi, Pooya Shariaty, Zaher Hashisho, Mojgan Daneshmand

Bibliographic record

VenueEnvironmental Science & Technology · 2016
Typearticle
Languageen
FieldEngineering
TopicAcoustic Wave Resonator Technologies
Canadian institutionsUniversity of Alberta
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsAdsorptionResonatorMicrowaveHigh resolutionMaterials scienceResolution (logic)OptoelectronicsProcess engineeringAnalytical Chemistry (journal)ChemistryChromatographyRemote sensingComputer scienceTelecommunicationsEngineeringOrganic chemistry

Abstract

fetched live from OpenAlex

A newly developed noncontact high-resolution real-time microwave sensor was used to determine the breakthrough time and adsorption capacity of adsorbents/adsorbates with different dielectric properties. The sensor is a microwave microstrip planar resonator with an enhanced quality factor using a regenerative feedback loop operating at 1.4 GHz and an adjustable quality factor of 200–200000. Beaded activated carbon (BAC, microwave-absorbing) and a polymeric adsorbent (V503, microwave transparent) were completely loaded with 1,2,4-trimethylbenzene (nonpolar) or 2-butoxyethanol (polar). During adsorption, variations in the dielectric properties of the adsorbents were monitored using two microwave parameters; quality factor and resonant frequency. Those parameters were related to adsorption breakthrough time and capacity. Adsorption tests were completed at select relative pressures (0.03, 0.1, 0.2, 0.4, and 0.6) of adsorbates in the influent stream. For all experiments, the difference between the breakthrough time ( t 5% ) and the settling time of the quality factor variation (time that the quality factor was 0.95 of its final value) was <5%. Additionally, a linear relationship between the final value of the resonant frequency shift and adsorption capacity was observed. The proposed noncontact sensor can be used to determine the breakthrough time and adsorption capacity.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.212
Teacher spread0.200 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2016
Admission routes2
Has abstractyes

Explore more

Same venueEnvironmental Science & TechnologySame topicAcoustic Wave Resonator TechnologiesFrench-language works237,207