MétaCan
Menu
← Back to cohort

Reasons for Failure to Remove Inferior Vena Cava Filters: Retrospective Study in a Tertiary Care and Trauma Centre

2011· article· en· W2561343461 on OpenAlexaff
Erica A. Peterson, Paul R. Yenson, David Liu, Andy W.J. Lee

Bibliographic record

VenueBlood · 2011
Typearticle
Languageen
FieldMedicine
TopicVenous Thromboembolism Diagnosis and Management
Canadian institutionsUniversity of British Columbia
Fundersnot available
KeywordsMedicinePulmonary embolismInferior vena cava filterRetrospective cohort studyInferior vena cavaPercutaneousUnivariate analysisSurgeryVenous thrombosisMultivariate analysisThrombosisInternal medicine

Abstract

fetched live from OpenAlex

Abstract Abstract 3141 Background: Inferior vena cava filter (IVCF) use has been rising exponentially since the introduction of percutaneous image guided IVCF placement and the subsequent development of optional recovery models. Optional recovery IVCFs are preferred over permanent devices as an alternative or adjunct to anticoagulation to prevent pulmonary embolism (PE) in patients with venous thromboembolism (VTE) due to their ability to be retrieved once they are no longer needed. In 2010, the US Food and Drug Administration issued a safety alert for optional recovery filters following reports of adverse events associated with their widespread use. Attempted removal rates reported in the literature are suboptimal, ranging from 15 to 70% in single centre studies. We conducted a retrospective study to determine IVCF complications, retrieval rates and barriers to removal in our institution. Methods: Consecutive patients who had a retrievable IVCF inserted or removed by the Interventional Radiology department from January 1st 2007 to June 30th 2010 were identified from a prospective database. Data were extracted from chart review using standardized forms. Outcomes collected included indication for IVCF, frequency of removal, documentation of an IVCF plan (for retrieval or not), reasons for non-retrieval, and all-cause mortality. A bivariate comparison of patients who had an attempted IVCF retrieval or not was performed. Patient characteristics were compared using 2-sided t-tests for continuous variables and chi-square analysis for categorical variables. Multivariate analysis by binary logistic regression was performed for significant variables (p<0.20) on univariate analysis. All statistics were performed using SPSS software. Results: 242 patients were identified with a median age of 60 years (range 14–93 y) of which 52.9% were male. Underlying thrombotic conditions included: acute (<3 months) VTE (76.9%), malignancy (35.1%) and trauma (21.5%). Indications for IVCF placement were acute (63.6%) or prior (8.3%) VTE with contraindication to anticoagulation, high risk of PE (14.5%) and primary prophylaxis (13.6%). A total of 37 patients died at a median of 13 d (range 1–66 d) after IVCF insertion. Retrieval was attempted in 58.1% (140/242 patients) and was successful in 89.9% (124 patients). The most common reason for failed retrieval attempt was filter thrombus (N=12). In the 33 patients with filter placement for primary prophylaxis 20 (60.6%) had a removal attempt with a success rate of 100%. Reasons for IVCF non-retrieval (102 patients) included death or limited life expectancy (N=39, 38.2%), plan to make the filter permanent (N=17, 16.7%), persistent/permanent contraindication to anticoagulation (N=14, 13.7%), persistent high risk of PE despite anticoagulation (N=2, 2%), planned indefinite anticoagulation (N=1, 0.98%), transfer to another province (N=2, 2%) and unknown/unspecified in chart (N=27, 26.5%). Predictors of attempted retrieval on multivariate analysis included documentation of filter plan (p<0.001) and age <70 years (p=0.016). In 27 patients (11.1%), removal was not attempted despite a lack of indication for IVCF to remain in situ; of these, 16 patients had no documented retrieval plan. Patients with no identifiable reason for non-retrieval were more likely to be cancer-free (p=0.010), admitted under a surgical service (p=0.009) and not have a consulting hematologist's involvement (p=0.041). Conclusion: Our single-centre IVC filter recovery rate compares favorably to published reports but remains suboptimal. Failure to document a filter plan and age > 70 years were the only predictors of a lower rate of attempted IVC filter recovery. A significant proportion of patients (11.1%) who did not undergo an attempted IVC filter recovery had no identifiable reason not to do so. Improper documentation may play a significant role in failure to recover devices, particularly in patients with no contraindications to removal. Further studies are needed to identify barriers to retrieval and improve removal rates. Disclosures: No relevant conflicts of interest to declare.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score0.019

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.006
Meta-epidemiology (narrow)0.0000.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.003
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.255
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueBlood→Same topicVenous Thromboembolism Diagnosis and Management→French-language works237,207→