MétaCan
Menu
Back to cohort
Record W2564611879 · doi:10.1515/rrlm-2016-0039

Comparison of four chromatographic methods used for measurement of glycated hemoglobin

2016· article· en· W2564611879 on OpenAlexaff
Enikő Nemes-Nagy, Zita Fazakas, V. Balogh-Sămărghițan, Zsuzsánna Simon-Szabó, Lóránd Dénes, Cosmina Cristina Uzun, Márta Andrea Fodor, Mariana Cornelia Tilinca, Deborah Reid, Trefor Higgins

Bibliographic record

VenueRevista română de medicină de laborator · 2016
Typearticle
Languageen
FieldMedicine
TopicDiabetes Management and Research
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsPipetteGlycated hemoglobinChromatographySpectrum analyzerGlycated haemoglobinHemoglobinGlycemicReagentMathematicsComputer scienceChemistryAnalytical Chemistry (journal)StatisticsBiomedical engineeringMedicineInternal medicineDiabetes mellitus

Abstract

fetched live from OpenAlex

Abstract This parameter’s results accuracy has a special importance in the management of diabetic patients since targets for optimal glycemic control are established using HbA1c values. Several error sources can influence the obtained value, some of them can be counteracted (ex. pipetting errors, storage), and others should be taken into consideration at the interpretation of the result (ex. presence of hemoglobin variants). The aim of this study was to compare four chromatographic methods regarding the costs and the influence of certain error sources on the accuracy of the result. Materials and methods: Samples and controls were analyzed using Variant I, Micromat II and In2it (Bio-Rad) systems, and the BIOMIDI reagent kit for HbA1c measurement. Results: Positive correlation could be observed comparing the results obtained using different methods, except the patients presenting elevated HbF. Pipetting errors modify the results up to 5% in case of Variant I, and up to 10% in case of Micromat II in the tested range. One day of improper storage at room temperature causes 3% deviation from the actual value using the Variant I analyzer and 5% in case of Micromat II and In2it equipment. As a conclusion, depending on the number of samples, automated chromatographic analyzers are the most appropriate equipments for the determination of HbA1c.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.009
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.021

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.009
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0030.002
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.082
GPT teacher head0.426
Teacher spread0.343 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueRevista română de medicină de laboratorSame topicDiabetes Management and ResearchFrench-language works237,207