MétaCan
Menu
Back to cohort
Record W2566663765 · doi:10.1097/opx.0000000000001038

Oxygen Tension Beneath Scleral Lenses of Different Clearances

2016· article· en· W2566663765 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueOptometry and Vision Science · 2016
Typearticle
Languageen
FieldMedicine
TopicCorneal surgery and disorders
Canadian institutionsUniversité de MontréalHôpital du Saint-Sacrement
Fundersnot available
KeywordsOphthalmologyTransmissibility (structural dynamics)Scleral lensCorneaChemistryOxygenOxygen tensionContact lensLens (geology)Analytical Chemistry (journal)Materials scienceOpticsMedicinePhysicsChromatography

Abstract

fetched live from OpenAlex

PURPOSE: To evaluate the relative partial pressure in oxygen (pO2) at the corneal surface under Boston XO2 scleral lenses (SL) fitted with targeted clearances of 200 and 400 μm (SL200 and SL400). METHODS: During this prospective study, the right eyes of eight normal subjects were fitted with SL200 and SL400. Clearance, validated after 5 minutes of wear with an optical coherence tomograph, was used with lens thicknesses to calculate transmissibility and estimate pO2. Corneal pO2s were measured with an oxygen electrode after 5 minutes of (1) corneal exposure to calibrating gases with various pO2 or of (2) SL wear. Decays in pO2 were modeled to an exponential. Linear regression between exponent k of these decays and calibrating gas pO2s allowed for the calculation of corneal pO2 under SL. Differences between pO2s beneath SL200 and SL400 were tested with a mixed ANOVA. RESULTS: The estimated transmissibility based on thicknesses and clearances (239.7 ± 34.7; 434.5 ± 33.2 μm) predicted a corneal pO2 of 8.52 ± 0.51 and 6.37 ± 0.28% for SL200 and SL400. These values were close to measured pO2: 9.07 ± 0.86 and 6.19 ± 0.87% (mean ± SEM) (P < .05) for SL200 and SL400, respectively. Both pO2 measurements fall short of the theoretical values needed to prevent hypoxia during lens wear (9.9% and above). CONCLUSIONS: As shown in vivo for the first time, an 18-mm scleral lens fitted with a 400-μm clearance reduces the oxygen tension available to the cornea by 30% compared to a similar lens fitted with a 200-μm clearance after 5 minutes of wear.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.657
Threshold uncertainty score0.196

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.384
Teacher spread0.363 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it