Oxygen Tension Beneath Scleral Lenses of Different Clearances
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
PURPOSE: To evaluate the relative partial pressure in oxygen (pO2) at the corneal surface under Boston XO2 scleral lenses (SL) fitted with targeted clearances of 200 and 400 μm (SL200 and SL400). METHODS: During this prospective study, the right eyes of eight normal subjects were fitted with SL200 and SL400. Clearance, validated after 5 minutes of wear with an optical coherence tomograph, was used with lens thicknesses to calculate transmissibility and estimate pO2. Corneal pO2s were measured with an oxygen electrode after 5 minutes of (1) corneal exposure to calibrating gases with various pO2 or of (2) SL wear. Decays in pO2 were modeled to an exponential. Linear regression between exponent k of these decays and calibrating gas pO2s allowed for the calculation of corneal pO2 under SL. Differences between pO2s beneath SL200 and SL400 were tested with a mixed ANOVA. RESULTS: The estimated transmissibility based on thicknesses and clearances (239.7 ± 34.7; 434.5 ± 33.2 μm) predicted a corneal pO2 of 8.52 ± 0.51 and 6.37 ± 0.28% for SL200 and SL400. These values were close to measured pO2: 9.07 ± 0.86 and 6.19 ± 0.87% (mean ± SEM) (P < .05) for SL200 and SL400, respectively. Both pO2 measurements fall short of the theoretical values needed to prevent hypoxia during lens wear (9.9% and above). CONCLUSIONS: As shown in vivo for the first time, an 18-mm scleral lens fitted with a 400-μm clearance reduces the oxygen tension available to the cornea by 30% compared to a similar lens fitted with a 200-μm clearance after 5 minutes of wear.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.000 | 0.001 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it