MétaCan
Menu
Back to cohort
Record W2577069570 · doi:10.1111/dom.12880

Outpatient 60‐hour day‐and‐night glucose control with dual‐hormone artificial pancreas, single‐hormone artificial pancreas, or sensor‐augmented pump therapy in adults with type 1 diabetes: <scp>A</scp> n open‐label, randomised, crossover, controlled trial

2017· article· en· W2577069570 on OpenAlexafffund
Ahmad Haidar, Virginie Messier, Laurent Legault, Martin Ladouceur, Rémi Rabasa‐Lhoret

Bibliographic record

VenueDiabetes Obesity and Metabolism · 2017
Typearticle
Languageen
FieldMedicine
TopicDiabetes Management and Research
Canadian institutionsMontreal Children's HospitalUniversité de MontréalMcGill University Health CentreMontreal Clinical Research InstituteMcGill University
FundersCanadian Institutes of Health Research
KeywordsArtificial pancreasHormoneMedicineEndocrinologyInternal medicineInsulinDiabetes mellitusGlucagonPancreasCrossover studyType 2 diabetesHormone therapyType 1 diabetesPathologyCancer

Abstract

fetched live from OpenAlex

AIMS: To assess whether the dual-hormone (insulin and glucagon) artificial pancreas reduces hypoglycaemia compared to the single-hormone (insulin alone) artificial pancreas in outpatient settings during the day and night. MATERIAL AND METHODS: In a randomized, three-way, crossover trial we compared the dual-hormone artificial pancreas, the single-hormone artificial pancreas and sensor-augmented pump therapy (control) in 23 adults with type 1 diabetes. Each intervention was applied from 8 AM Day 1 to 8 PM Day 3 (60 hours) in outpatient free-living conditions. The primary outcome was time spent with sensor glucose levels below 4.0 mmol/L. A P value of less than .017 was regarded as significant. RESULTS: The median difference between the dual-hormone system and the single-hormone system was -2.3% (P = .072) for time spent below 4.0 mmol/L, -1.3% (P = .017) for time below 3.5 mmol/L, and -0.7% (P = .031) for time below 3.3 mmol/L. Both systems reduced (P < .017) hypoglycaemia below 4.0, 3.5 and 3.3 mmol/L compared to control therapy, but reductions were larger with the dual-hormone system than with the single-hormone system (medians -4.0% vs -3.4% for 4.0 mmol/L; -2.7% vs -2.2% for 3.5 mmol/L; and -2.2% vs -1.2% for 3.3 mmol/L). There were 34 hypoglycaemic events (<3.0 mmol/L for 20 minutes) with control therapy, 14 with the single-hormone system and 6 with the dual-hormone system. These differences in hypoglycaemia were observed while mean glucose level was low and comparable in all interventions (P = NS). CONCLUSIONS: The dual-hormone artificial pancreas had the lowest risk of hypoglycaemia, but the differences were not statistically significant. Larger studies are needed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Scholarly communication
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.093
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.002
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0030.000
Bibliometrics0.0000.000
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.271
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations76
Published2017
Admission routes2
Has abstractyes

Explore more

Same venueDiabetes Obesity and MetabolismSame topicDiabetes Management and ResearchFrench-language works237,207