MétaCan
Menu
Back to cohort
Record W2580618614

Application of Carbon Dioxide in a Transcritical Refrigeration Cycle

2007· article· en· W2580618614 on OpenAlexaboutno aff
Dario Hrastović, Vladimir Soldo, Marino Grozdek

Bibliographic record

VenueStrojarstvo · 2007
Typearticle
Languageen
FieldEngineering
TopicRefrigeration and Air Conditioning Technologies
Canadian institutionsnot available
Fundersnot available
KeywordsRefrigerantTranscritical cycleRefrigerationVapor-compression refrigerationCoefficient of performanceThermodynamicsAir source heat pumpsCarbon dioxideHeat pump and refrigeration cycleEnvironmental scienceProcess engineeringChemistryGas compressorEngineering
DOInot available

Abstract

fetched live from OpenAlex

During the last century, the refrigeration industry was forced to change refrigerant technology due to commitments to the Montreal protocol. The industry is redesigning technology towards the application of new environment friendly refrigerants that may be used for a longer period. Refrigerants should be chlorine free, which means that they do not have impact on the ozone layer, and at the same time they should have low global warming potential. Emphasis in this paper is given to the use of carbon-dioxide R744 and ammonia R717 because of their low impact on the atmosphere. The cascade system technology is known with CO2 as the refrigerant in the first stage and NH3 as the refrigerant in the second stage of the cascade. This paper elaborates the use of CO2 in the transcritical area, i.e. above the critical point where there is no vapour condensation. The paper deals also with problems connected with high working pressure of CO2, thermodynamic properties and design of transcritical heat pumps and their components. Compared to other refrigerants, CO2 has one specific property: low critical temperature 31, 1 °C at 73, 8 bar. The operating pressure for gas cooling will be extremely high, above 100 bar. In the subcritical area the enthalpy change is influenced by the temperature change, while in transcritical area enthalpy change is affected by pressure. In the transcritical area, the coefficient of performance may be controlled by the refrigerant pressure after compression.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.112
Threshold uncertainty score0.283

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.230
Teacher spread0.224 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueStrojarstvoSame topicRefrigeration and Air Conditioning TechnologiesFrench-language works237,207