MétaCan
Menu
Back to cohort
Record W2581052528 · doi:10.1097/prs.0000000000003010

Infant Robotic Cleft Palate Surgery: A Feasibility Assessment Using a Realistic Cleft Palate Simulator

2017· article· en· W2581052528 on OpenAlexaff
Dale J. Podolsky, David M. Fisher, Karen W. Y. Wong Riff, Thomas Looi, James M. Drake, Christopher R. Forrest

Bibliographic record

VenuePlastic & Reconstructive Surgery · 2017
Typearticle
Languageen
FieldMedicine
TopicSurgical Simulation and Training
Canadian institutionsHospital for Sick ChildrenUniversity of Toronto
FundersIntuitive Surgical
KeywordsMedicineWristRobotic surgeryRobotic armOrthodonticsSurgeryArtificial intelligenceComputer science

Abstract

fetched live from OpenAlex

BACKGROUND: A surgical robot offers enhanced precision, visualization, and access and the potential to improve outcomes in cleft palate surgery. The goal of this study was to investigate the feasibility of using the da Vinci robot for cleft palate repair in infants using a cleft palate simulator test bed. METHODS: A high-fidelity cleft palate simulator was developed that allows performance of a robotic cleft palate repair procedure. A complete cleft palate repair was performed with the da Vinci Si with 5-mm instruments and the da Vinci Xi with 8-mm instruments. The advantages of the robotic approach were assessed in comparison with using standard instruments. For each system, arm repositioning, collisions, instrument and endoscope excursion, wrist orientation, and vision were compared for 12 steps of the repair. RESULTS: The cleft palate simulator provided a reproducible platform for testing robotic cleft palate surgery. The advantages of the robotic approach were the ability to articulate a miniature wrist intraorally with superior visualization, increased ambidexterity, and improved ergonomics compared with using standard instruments. Cleft palate repair with the Xi was superior to the Si with respect to arm repositioning, instrument collisions and excursion, and wrist orientation. However, Xi performance remained suboptimal because of the larger instruments. CONCLUSIONS: Robotic cleft palate repair using the da Vinci system offers advantages compared with the traditional approach. Cleft palate repair is more feasible with the Xi and 8-mm instruments. However, performance is limited by the instrumentation, which requires modification to ensure safety and efficacy. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, V.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.004
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.089
GPT teacher head0.350
Teacher spread0.261 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations42
Published2017
Admission routes1
Has abstractyes

Explore more

Same venuePlastic & Reconstructive SurgerySame topicSurgical Simulation and TrainingFrench-language works237,207