MétaCan
Menu
Back to cohort
Record W2581270879 · doi:10.1002/jmri.25622

Topologically preserving straightening of spinal cord MRI

2017· article· en· W2581270879 on OpenAlexafffund
Benjamin De Leener, Gabriel Mangeat, Sara M. Dupont, Allan R. Martin, Virginie Callot, Nikola Stikov, Michael G. Fehlings, Julien Cohen‐Adad

Bibliographic record

VenueJournal of Magnetic Resonance Imaging · 2017
Typearticle
Languageen
FieldMedicine
TopicCervical and Thoracic Myelopathy
Canadian institutionsUniversité de MontréalMontreal Heart InstituteUniversity of TorontoPolytechnique Montréal
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health ResearchCompute Canada
KeywordsSpinal cordSegmentationMagnetic resonance imagingVoxelMedicineRobustness (evolution)AlgorithmMathematicsComputer scienceArtificial intelligenceRadiology

Abstract

fetched live from OpenAlex

Purpose To propose a robust and accurate method for straightening magnetic resonance (MR) images of the spinal cord, based on spinal cord segmentation, that preserves spinal cord topology and that works for any MRI contrast, in a context of spinal cord template‐based analysis. Materials and Methods The spinal cord curvature was computed using an iterative Non‐Uniform Rational B‐Spline (NURBS) approximation. Forward and inverse deformation fields for straightening were computed by solving analytically the straightening equations for each image voxel. Computational speed‐up was accomplished by solving all voxel equation systems as one single system. Straightening accuracy (mean and maximum distance from straight line), computational time, and robustness to spinal cord length was evaluated using the proposed and the standard straightening method (label‐based spline deformation) on 3T T 2 ‐ and T 1 ‐weighted images from 57 healthy subjects and 33 patients with spinal cord compression due to degenerative cervical myelopathy (DCM). Results The proposed algorithm was more accurate, more robust, and faster than the standard method (mean distance = 0.80 vs. 0.83 mm, maximum distance = 1.49 vs. 1.78 mm, time = 71 vs. 174 sec for the healthy population and mean distance = 0.65 vs. 0.68 mm, maximum distance = 1.28 vs. 1.55 mm, time = 32 vs. 60 sec for the DCM population). Conclusion A novel image straightening method that enables template‐based analysis of quantitative spinal cord MRI data is introduced. This algorithm works for any MRI contrast and was validated on healthy and patient populations. The presented method is implemented in the Spinal Cord Toolbox, an open‐source software for processing spinal cord MRI data. Level of Evidence: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1209–1219.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.918
Threshold uncertainty score0.736

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.027
GPT teacher head0.332
Teacher spread0.305 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations30
Published2017
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Magnetic Resonance ImagingSame topicCervical and Thoracic MyelopathyFrench-language works237,207