MétaCan
Menu
Back to cohort
Record W2584164846 · doi:10.1515/cclm-2016-0947

Variant peptide detection utilizing mass spectrometry: laying the foundations for proteogenomic identification and validation

2017· article· en· W2584164846 on OpenAlexaff
Lampros Dimitrakopoulos, Ioannis Prassas, Els M.J.J. Berns, John A. Foekens, Eleftherios P. Diamandis, George S. Charames

Bibliographic record

VenueClinical Chemistry and Laboratory Medicine (CCLM) · 2017
Typearticle
Languageen
FieldChemistry
TopicAdvanced Proteomics Techniques and Applications
Canadian institutionsLunenfeld-Tanenbaum Research InstituteUniversity Health NetworkUniversity of TorontoMount Sinai Hospital
Fundersnot available
KeywordsProteogenomicsMass spectrometryIdentification (biology)Computational biologyPeptideChromatographyChemistryBiologyBiochemistry

Abstract

fetched live from OpenAlex

BACKGROUND: Proteogenomics is an emerging field at the intersection of genomics and proteomics. Many variant peptides corresponding to single nucleotide variations (SNVs) are associated with specific diseases. The aim of this study was to demonstrate the feasibility of proteogenomic-based variant peptide detection in disease models and clinical specimens. METHODS: We sought to detect p53 single amino acid variant (SAAV) peptides in breast cancer tumor samples that have been previously subjected to sequencing analysis. Initially, two cancer cell lines having a cellular tumor antigen p53 (TP53) mutation and one wild type for TP53 were analyzed by selected reaction monitoring (SRM) assays as controls. One pool of wild type and one pool of mutated for TP53 cytosolic extracts were assayed with a shotgun proteogenomic workflow. Furthermore, 18 individual samples having a mutation in TP53 were assayed by SRM. RESULTS: Two mutant p53 peptides were successfully detected in two cancer cell lines as expected from their DNA sequence. Wild type p53 peptides were detected in both cytosolic pools, however, none of the mutant p53 peptides were identified. Mutations at the protein level were detected in two cytosolic extracts and whole tumor lysates from the same patients by SRM analysis. Six thousand and six hundred and twenty eight non-redundant proteins were identified in the two cytosolic pools, thus greatly improving a previously reported cytosolic proteome. CONCLUSIONS: In the current study we show the great potential of using proteogenomics for the direct identification of cancer-associated mutations in clinical samples and we discuss current limitations and future perspectives.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.005
Threshold uncertainty score0.028

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0050.004
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0000.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.055
GPT teacher head0.376
Teacher spread0.320 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueClinical Chemistry and Laboratory Medicine (CCLM)Same topicAdvanced Proteomics Techniques and ApplicationsFrench-language works237,207