Evaluation of the optimal cuff volume and cuff pressure of the revised laryngeal tube “LTS-D” in surgical patients

2017· article· en· W2584854782 on OpenAlexaff
Marc Kriege, Christian Alflen, Johannes Eisel, Thomas Ott, T. Piepho, Ruediger Noppens

Bibliographic record

VenueBMC Anesthesiology · 2017
Typearticle
Languageen
FieldMedicine
TopicAirway Management and Intubation Techniques
Canadian institutionsLondon Health Sciences CentreWestern University
Fundersnot available
KeywordsCuffMedicineInterquartile rangeLeakAirwayAnesthesiaLaryngeal mask airwayMechanical ventilationVentilation (architecture)Surgery

Abstract

fetched live from OpenAlex

Recent case reports have indicated significant cuff overinflation when using the standard filling volume based on the manufacturer’s recommendations in older models of laryngeal tubes. The aim of this study was to determine the minimum cuff pressure needed to perform standardized ventilation without leakage in the new, revised model of the laryngeal tube “LTS-D”. After ethical approval, LTS-D was placed for ventilation in 60 anesthetized patients. The cuff was inflated to the recommended volume (#3: 60 ml, #4: 80 ml, and #5: 90 ml). After evaluation of the initial cuff pressure (CP), the CP was lowered in 10 cmH2O steps until a minimal cuff pressure of 30 cmH2O was achieved. The absence of an audible leak was required for a step-by-step reduction in the CP. Evacuated cuff volume, success rate, and airway injuries were documented. Data were expressed as medians (interquartile ranges [IQRs]). The comparison of CPs and cuff volumes was performed using the Mann-Whitney test. After initial inflation, the CP ranged from 105 cmH2O [90–120; #5] to 120 cmH2O [110–120; #3]. Lowering the CP to 60 cmH2O resulted in a reduced cuff volume ranging from 47 ml [44–54; #3] to 77 ml [75–82; #5] compared to the initial inflation (p < 0.001). Leakage occurred more frequently when the CP was lowered to 40 cmH2O compared to the initial inflation (44/54 [81%]; p < 0.01). Using a CP between 50 cmH2O and 60 cmH2O, a leakage rate of 3/54 (5%) was observed, compared to a rate of 11/54 (21%) when using a CP lower than 50 cmH2O. The overall success rate was 90%, and airway injury occurred in 7% of patients (4/60). We found significant overinflation of the revised LTS-D using the recommended volume for initial cuff inflation. A CP of 60 cmH2O was found to be sufficient for ventilation in the majority of patients evaluated. Checking and adjusting the CP in laryngeal tubes is mandatory to avoid overinflation. ClinicalTrials.gov NCT02300337 . Registered: 20 November 2014.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.011
Threshold uncertainty score0.185

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.034
GPT teacher head0.305
Teacher spread0.270 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueBMC AnesthesiologySame topicAirway Management and Intubation TechniquesFrench-language works237,207