The correction of time and temperature effects in MR-based 3D Fricke xylenol orange dosimetry
Bibliographic record
Abstract
Abstract Previously developed MR-based three-dimensional (3D) Fricke-xylenol orange (FXG) dosimeters can provide end-to-end quality assurance and validation protocols for pre-clinical radiation platforms. FXG dosimeters quantify ionizing irradiation induced oxidation of Fe 2+ ions using pre- and post-irradiation MR imaging methods that detect changes in spin-lattice relaxation rates ( R 1 = T 1 − 1 ) caused by irradiation induced oxidation of Fe 2+ . Chemical changes in MR-based FXG dosimeters that occur over time and with changes in temperature can decrease dosimetric accuracy if they are not properly characterized and corrected. This paper describes the characterization, development and utilization of an empirical model-based correction algorithm for time and temperature effects in the context of a pre-clinical irradiator and a 7 T pre-clinical MR imaging system. Time and temperature dependent changes of R 1 values were characterized using variable TR spin-echo imaging. R 1 -time and R 1 -temperature dependencies were fit using non-linear least squares fitting methods. Models were validated using leave-one-out cross-validation and resampling. Subsequently, a correction algorithm was developed that employed the previously fit empirical models to predict and reduce baseline R 1 shifts that occurred in the presence of time and temperature changes. The correction algorithm was tested on R 1 -dose response curves and 3D dose distributions delivered using a small animal irradiator at 225 kVp. The correction algorithm reduced baseline R 1 shifts from −2.8 × 10 −2 s −1 to 1.5 × 10 −3 s −1 . In terms of absolute dosimetric performance as assessed with traceable standards, the correction algorithm reduced dose discrepancies from approximately 3% to approximately 0.5% (2.90 ± 2.08% to 0.20 ± 0.07%, and 2.68 ± 1.84% to 0.46 ± 0.37% for the 10 × 10 and 8 × 12 mm 2 fields, respectively). Chemical changes in MR-based FXG dosimeters produce time and temperature dependent R 1 values for the time intervals and temperature changes found in a typical small animal imaging and irradiation laboratory setting. These changes cause baseline R 1 shifts that negatively affect dosimeter accuracy. Characterization, modeling and correction of these effects improved in-field reported dose accuracy to less than 1% when compared to standardized ion chamber measurements.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.003 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.002 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".