MétaCan
Menu
Back to cohort
Record W2587800676 · doi:10.1109/ecce.2016.7855161

High-frequency six pulse DC link based bidirectional three-phase inverter without intermediate decoupling capacitor

2016· article· en· W2587800676 on OpenAlexaff
Anirban Ghoshal, Dorai B Yelaverthy, Akshay Kumar Rathore, Ranjit Mahanty

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicAdvanced DC-DC Converters
Canadian institutionsConcordia University
Fundersnot available
KeywordsPulse-width modulationCapacitorInverterDecoupling capacitorElectrical engineeringElectronic engineeringVoltageComputer scienceEngineering

Abstract

fetched live from OpenAlex

Cascaded bidirectional dc-ac converters are commonly used in UPS application and battery chargers for electric vehicles (EV). A bidirectional dual active bridge cascaded three phase converter (DABCC) with six pulse dc link, high reliability and low cost is proposed for applications like line interactive UPS and EV. Power conversion units for such applications use large electrolytic capacitor at high voltage DC bus. Through a novel modulation technique Six Pulse Modulation (SPM), this electrolytic capacitor is eliminated that results in increased reliability, compactness and reduced cost. It needs only single H-bridge and one single-phase transformer at front-end for the required three-phase conversion. SPM technique also increases DC bus utilization and decreases the inverter average switching frequency to 33% when compared to traditional sine PWM. To effectively implement the SPM modulation, a fast dynamic control of dc link voltage is required. For that a coordinated control is implemented. And also the effect of dead time on the inverter terminal voltage for a SPM modulated converter is analyzed and its effect on terminal voltage is presented. To mitigate this effect, a compensation technique based on resonant control is proposed. RMS current stress for high voltage dc link capacitor is studied and it is shown that the capacitor requirement for SPM modulation is lower than the conventional Sine Pulse Width Modulation (SPWM). To validate the proposed control scheme, a 800 W prototype is fabricated. Hardware results are presented to show the effectiveness of the implemented control scheme.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.233
Teacher spread0.222 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".