MétaCan
Menu
Back to cohort
Record W2588098184 · doi:10.1097/icl.0000000000000366

A Review of Techniques to Measure Protein Sorption to Soft Contact Lenses

2017· review· en· W2588098184 on OpenAlexaff
Brad Hall, James A. Forrest, Lyndon Jones

Bibliographic record

VenueEye & Contact Lens Science & Clinical Practice · 2017
Typereview
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsPerimeter InstituteUniversity of Waterloo
Fundersnot available
KeywordsMeasure (data warehouse)Contact lensSorptionLens (geology)In situChemistryBiological systemMaterials scienceNanotechnologyOpticsComputer sciencePhysicsBiologyData miningAdsorption

Abstract

fetched live from OpenAlex

PURPOSE: To compare and critically evaluate a variety of techniques to measure the quantity and biological activity of protein sorption to contact lenses over short time periods. METHODS: A literature review was undertaken investigating the major techniques to measure protein sorption to soft contact lens materials, with specific reference to measuring protein directly on lenses using in situ, ex situ, protein structural, and biological activity techniques. RESULTS: The use of in situ techniques to measure protein quantity provides excellent sensitivity, but many are not directly applicable to contact lenses. Many ex situ techniques struggle to measure all sorbed proteins, and these measurements can have significant signal interference from the lens materials themselves. Techniques measuring the secondary and tertiary structures of sorbed proteins have exhibited only limited success. CONCLUSIONS: There are a wide variety of techniques to measure both the amount of protein and the biological activity of protein sorbed to soft contact lens materials. To measure the mass of protein sorbed to soft contact lenses (not just thin films) over short time periods, the method of choice should be I radiolabeling. This technique is sensitive enough to measure small amounts of deposited protein, provided steps are taken to limit and measure any interaction of the iodine tracer with the materials. To measure the protein activity over short time periods, the method of choice should be to measure the biological function of sorbed proteins. This may require new methods or adaptations of existing ones.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.006
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0060.004
Science and technology studies0.0000.001
Scholarly communication0.0010.002
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.226
GPT teacher head0.513
Teacher spread0.288 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueEye & Contact Lens Science & Clinical PracticeSame topicOcular Surface and Contact LensFrench-language works237,207