MétaCan
Menu
Back to cohort
Record W2591576413 · doi:10.1177/1533034616681674

Positional Accuracy of Treating Multiple Versus Single Vertebral Metastases With Stereotactic Body Radiotherapy

2016· article· en· W2591576413 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueTechnology in Cancer Research & Treatment · 2016
Typearticle
Languageen
FieldMedicine
TopicManagement of metastatic bone disease
Canadian institutionsBC Cancer AgencyUniversity of TorontoSunnybrook Health Science Centre
Fundersnot available
KeywordsMedicineRadiation treatment planningRadiosurgeryRadiation therapyNuclear medicineVertebral bodyIsocenterRadiologySurgery

Abstract

fetched live from OpenAlex

The aim of this study is to determine whether stereotactic body radiotherapy for multiple vertebral metastases treated with a single isocenter results in greater intrafraction errors than stereotactic body radiotherapy for single vertebral metastases and to determine whether the currently used spinal cord planning organ at risk volume and planning target volume margins are appropriate. Intrafraction errors were assessed for 65 stereotactic body radiotherapy treatments for vertebral metastases. Cone beam computed tomography images were acquired before, during, and after treatment for each fraction. Residual translational and rotational errors in patient positioning were recorded and planning organ at risk volume and planning target volume margins were calculated in each direction using this information. The mean translational residual errors were smaller for single (0.4 (0.4) mm) than for multiple vertebral metastases (0.5 (0.7) mm; P = .0019). The mean rotational residual errors were similar for single (0.3° (0.3°) and multiple vertebral metastases (0.3° (0.3°); P = .862). The maximum calculated planning organ at risk volume margin in any direction was 0.83 mm for single and 1.22 for multiple vertebral metastases. The maximum calculated planning target volume margin in any direction was 1.4 mm for single and 1.9 mm for multiple vertebral metastases. Intrafraction errors were small for both single and multiple vertebral metastases, indicating that our strategy for patient immobilization and repositioning is robust. Calculated planning organ at risk volume and planning target volume margins were smaller than our clinically employed margins, indicating that our clinical margins are appropriate.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.371
Threshold uncertainty score0.684

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.100
GPT teacher head0.422
Teacher spread0.322 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it