MétaCan
Menu
Back to cohort
Record W2593077520

Investigation of Sub-Pitch Spatial Resolution for Pixelated CZT X-Ray Detector

2017· dissertation· en· W2593077520 on OpenAlexaboutno aff
Yike Li

Bibliographic record

VenueMacSphere (McMaster University) · 2017
Typedissertation
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsnot available
Fundersnot available
KeywordsResolution (logic)DetectorOpticsX-rayImage resolutionX-ray detectorPhysicsMaterials scienceComputer scienceArtificial intelligence
DOInot available

Abstract

fetched live from OpenAlex

As everyone knows, cancer is one of the greatest health enemies of mankind and became a major public health problem all over the world. Moreover, lung cancer is the most common global cancer leading to more than 1.3 million estimated deaths annually worldwide. Breast cancer is the most common cancer and the 2nd leading cause of death from in women in the US, Canada, and China. Therefore an instrument for the early diagnosis and monitoring of cancers in areas such as lung and breast is immensely important and necessary. The cadmium zinc telluride (CZT) semiconductor is a kind of novel radiation detector that can provide detailed information about spatial position. Also, the energy resulting from interactions between the radiation and the CZT material can also be assessed giving this type of detector added value in disease evaluation. A great deal of work on CZT detectors has been done for breast CT scanning. Furthermore, the CZT detector is also a potential solution for problems in lung cancer CT evaluation where the lack of energy information and high radiation exposure are less than ideal. Since sub-millimetre spatial resolution is required for post-contrast thoracic CT assessment, and $100~\mu m$ or better is critical for breast CT, the investigation of spatial resolution for CZT detectors is essential. In this thesis, the interactions within CZT detectors were analyzed. The influence of different configurations, including adjustment of anode size, gap size, detector thickness and bias voltage, were discussed. Next the methods to evaluate two kinds of signals (collected and transit signals), are provided in Chapter~2. In Chapter~3, an intensity difference method and an intensity ratio method for estimating the sub-pitch spatial resolution were described in detail. Finally, a detector spatial resolution between $10~\mu m$ and $20~\mu m$ was achieved using the collecting signal intensities ratio method and a $4~mm$ thick CZT detector with gap size of $g=50~\mu m$ and bias voltage of $V=300V$. Future work should focus on the contributions from characteristic X-rays emitted from cadmium and tellurium atoms. Also, the work presented was only on pixelated arrays and further assessment of cross-strip electrode detectors could also be of benefit. Lastly based on simulations done in this thesis all photons were assumed to strike the cathode at 90 degrees. Future work should also include non-orthogonal directions for photons.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Other · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.198
Teacher spread0.186 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreOther

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueMacSphere (McMaster University)Same topicAdvanced X-ray and CT ImagingFrench-language works237,207