MétaCan
Menu
← Back to cohort
Record W2593299994 · doi:10.1117/12.2256004

Monitoring electromagnetic tracking error using redundant sensors

2017· article· en· W2593299994 on OpenAlexaff
Vinyas Harish, Eden Bibic, András Lassó, Matthew Holden, Thomas Vaughan, Zachary M. C. Baum, Tamás Ungi, Gábor Fichtinger

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2017
Typearticle
Languageen
FieldMedicine
TopicSurgical Simulation and Training
Canadian institutionsQueen's University
Fundersnot available
KeywordsComputer scienceWorkspaceTracking errorObservational errorTracking (education)Computer visionClassifier (UML)Artificial intelligenceError detection and correctionSensitivity (control systems)AlgorithmElectronic engineeringMathematics

Abstract

fetched live from OpenAlex

PURPOSE: The intraoperative measurement of tracking error is crucial to ensure the reliability of electromagnetically navigated procedures. For intraoperative use, methods need to be quick to set up, easy to interpret, and not interfere with the ongoing procedure. Our goal was to evaluate the feasibility of using redundant electromagnetic sensors to alert users to tracking error in a navigated intervention setup. METHODS: Electromagnetic sensors were fixed to a rigid frame around a region of interest and on surgical tools. A software module was designed to detect tracking error by comparing real-time measurements of the differences between inter-sensor distances and angles to baseline measurements. Once these measurements were collected, a linear support vector machine-based classifier was used to predict tracking errors from redundant sensor readings. RESULTS: Measuring the deviation in the reported inter-sensor distance and angle between the needle and cautery served as a valid indicator for electromagnetic tracking error. The highest classification accuracy, 86%, was achieved based on readings from the cautery when the two sensors on the cautery were close together. The specificity of this classifier was 93% and the sensitivity was 82%. CONCLUSION: Placing redundant electromagnetic sensors in a workspace seems to be feasible for the intraoperative detection of electromagnetic tracking error in controlled environments. Further testing should be performed to optimize the measurement error threshold used for classification in the support vector machine, and improve the sensitivity of our method before application in real procedures.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.010
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.010
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.036
GPT teacher head0.296
Teacher spread0.261 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE→Same topicSurgical Simulation and Training→French-language works237,207→