Hybrid carbon nanotube-polymer scaffolds for cardiac tissue regeneration
Bibliographic record
Abstract
Due to insufficient supply of heart transplants and limited regenerative ability of heart tissues, cardiac tissue engineering has emerged to restore or regenerate the structure and function of native cardiac tissues. Scaffolds play a major role in fabrication of functional cardiac tissues, providing structural support, biodegradation, and cell affinity. However, currently used scaffolds in cardiac tissue regeneration tend to lack adequate electrical conductivity and favorable mechanical properties. In response to these concerns, carbon nanotubes (CNTs) have been used to enhance electrical and mechanical properties of scaffolds in cardiac tissue engineering. Here, we review different hybrid CNT-biomaterial scaffolds, both natural and synthetic, in cardiac tissue regeneration and their fabrication methods. Furthermore, CNT toxicity is also discussed. We further outline future trends in this research area toward using CNTs as a functional nanomaterial in cardiac tissue engineering.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".