MétaCan
Menu
Back to cohort
Record W2594005933 · doi:10.1159/000457807

Three-Dimensional Printing of a Transconjunctival Vitrectomy Trocar-Cannula System

2017· article· en· W2594005933 on OpenAlexaff
Eduardo V. Navajas, Martin ten Hove

Bibliographic record

VenueOphthalmologica · 2017
Typearticle
Languageen
FieldMedicine
TopicRetinal and Macular Surgery
Canadian institutionsQueen's UniversityUniversity of British Columbia
Fundersnot available
KeywordsCannulaVitreoretinal surgeryVitrectomyBiomedical engineeringMedicineSurgery

Abstract

fetched live from OpenAlex

PURPOSE: The aim of this paper was to study the feasibility of manufacturing a customizable trocar-cannula system for vitreoretinal surgery utilizing commercially available three-dimensional (3D) printing technology. METHODS: A digital model of a trocar-cannula system for vitreoretinal surgery was created using computer-aided design (CAD) software and printed utilizing a laser-sintering 3D printer in modified ABS thermoplastic material. The trocar-cannula prototypes were tested in pig eyes. RESULTS: A customizable digital model was created using commercially available CAD software. Three trocar-cannulas were printed. The smallest cannulas that could be printed had dimensions between 21 and 22G. The trocar-cannulas were inserted in pig eyes after performing sclerotomies with a commercially available 20G MVR blade. One cannula broke during insertion. CONCLUSIONS: This study demonstrates the feasibility of printing a transconjunctival vitrectomy trocar-cannula system with commercially available 3D print technology. The 3D printer and build material used resulted in trocar-cannulas with functional limitations including a minimum size achievable and mechanical resistance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.039
GPT teacher head0.293
Teacher spread0.253 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueOphthalmologicaSame topicRetinal and Macular SurgeryFrench-language works237,207