MétaCan
Menu
Back to cohort
Record W2595101390 · doi:10.3171/2016.10.jns161731

The second-generation eCLIPs Endovascular Clip System: initial experience

2017· article· en· W2595101390 on OpenAlexaff
Albert Chiu, Joost de Vries, Cian O′Kelly, Howard A. Riina, Ian McDougall, Jonathan Tippett, Martina Wan, Airton Leonardo de Oliveira Manoel, Thomas R. Marotta

Bibliographic record

VenueJournal of neurosurgery · 2017
Typearticle
Languageen
FieldMedicine
TopicIntracranial Aneurysms: Treatment and Complications
Canadian institutionsCisco Systems (Canada)St. Michael's HospitalUniversity of CalgaryUniversity of AlbertaUniversity of Toronto
Fundersnot available
KeywordsMedicineAsymptomaticSurgeryAneurysmEndovascular treatmentStentComplicationRadiology

Abstract

fetched live from OpenAlex

OBJECTIVE Treatment of wide-necked intracranial aneurysms is associated with higher recanalization and complication rates; however, the most commonly used methods are not specifically designed to work in bifurcation lesions. To address these issues, the authors describe the evolution in the design and use of the eCLIPs (Endovascular Clip System) device, a novel hybrid stent-like assist device with flow diverter properties that was first described in 2008. METHODS A registry was established covering 13 international centers at which patients were treated with the second-generation eCLIPs device. Aneurysm morphology and rupture status, device neck coverage, coil retention, and procedural and late morbidity and mortality were recorded. For those patients who had undergone successful implantation more than 6 months earlier, the final imaging and clinical follow-up results and need for re-treatment were recorded. RESULTS Thirty-three patients were treated between June 2013 and September 2015. Twenty-five (76%) patients had successful placement of an eCLIPs device; 23 (92%) of these 25 patients had complete data. Eight cases of nondeployment occurred during the 1st year of use, consistent with a learning curve; no failures of deployment occurred thereafter. Two periprocedural transient ischemic attacks and 2 asymptomatic thrombotic events occurred. Twenty-one (91%) of 23 patients underwent follow-up at an average of 8 months (range 3-18 months); 9 (42.9%) of these 21 patients demonstrated an improvement in Raymond grade at follow-up; no cases of worsening Raymond grade were recorded, and 17 (81.0%) patients sustained a modified Raymond-Roy Classification class of I or II angiographic result at follow-up. Two delayed ruptures were recorded, both in previously coiled, symptomatic giant aneurysms where the device was used as a part of a salvage strategy. CONCLUSIONS The second-generation eCLIPs device is a viable treatment option for bifurcation aneurysms. The aneurysm occlusion rates in this initial clinical series are comparable to the initial experience with other bifurcation support devices.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.710
Threshold uncertainty score0.741

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0010.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.058
GPT teacher head0.308
Teacher spread0.250 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations52
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueJournal of neurosurgerySame topicIntracranial Aneurysms: Treatment and ComplicationsFrench-language works237,207