Outcomes in Transcatheter Aortic Valve Replacement for Bicuspid Versus Tricuspid Aortic Valve Stenosis
Bibliographic record
Abstract
BACKGROUND: Transcatheter aortic valve replacement (TAVR) is being increasingly performed in patients with bicuspid aortic valve stenosis (AS). OBJECTIVES: This study sought to compare the procedural and clinical outcomes in patients with bicuspid versus tricuspid AS from the Bicuspid AS TAVR multicenter registry. METHODS: Outcomes of 561 patients with bicuspid AS and 4,546 patients with tricuspid AS were compared after propensity score matching, assembling 546 pairs of patients with similar baseline characteristics. Procedural and clinical outcomes were recorded according to Valve Academic Research Consortium-2 criteria. RESULTS: Compared with patients with tricuspid AS, patients with bicuspid AS had more frequent conversion to surgery (2.0% vs. 0.2%; p = 0.006) and a significantly lower device success rate (85.3% vs. 91.4%; p = 0.002). Early-generation devices were implanted in 320 patients with bicuspid and 321 patients with tricuspid AS, whereas new-generation devices were implanted in 226 and 225 patients with bicuspid and tricuspid AS, respectively. Within the group receiving early-generation devices, bicuspid AS had more frequent aortic root injury (4.5% vs. 0.0%; p = 0.015) when receiving the balloon-expanding device, and moderate-to-severe paravalvular leak (19.4% vs. 10.5%; p = 0.02) when receiving the self-expanding device. Among patients with new-generation devices, however, procedural results were comparable across different prostheses. The cumulative all-cause mortality rates at 2 years were comparable between bicuspid and tricuspid AS (17.2% vs. 19.4%; p = 0.28). CONCLUSIONS: Compared with tricuspid AS, TAVR in bicuspid AS was associated with a similar prognosis, but lower device success rate. Procedural differences were observed in patients treated with the early-generation devices, whereas no differences were observed with the new-generation devices.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.002 | 0.007 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".