Microwaves-Based High Sensitivity Sensors for Crack Detection in Metallic Materials
Bibliographic record
Abstract
This paper presents a highly sensitive sensor for crack detection in metallic surfaces. The sensor is inspired by complementary split-ring resonators which have dimensions much smaller than the excitation's wavelength. The entire sensor is etched in the ground plane of a microstrip line and fabricated using printed circuit board technology. Compared to available microwave techniques, the sensor introduced here has key advantages including high sensitivity, increased dynamic range, spatial resolution, design simplicity, selectivity, and scalability. Experimental measurements showed that a surface crack having 200-μm width and 2-mm depth gives a shift in the resonance frequency of 1.5 GHz. This resonance frequency shift exceeds what can be achieved using other sensors operating in the low GHz frequency regime by a significant margin. In addition, using numerical simulation, we showed that the new sensor is able to resolve a 10-μm-wide crack (equivalent to λ/4000) with 180-MHz shift in the resonance frequency.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.001 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".