MétaCan
Menu
Back to cohort
Record W2597576088 · doi:10.1002/jemt.22869

Quality evaluation of ultra‐thin samples: Application to graphene

2017· article· en· W2597576088 on OpenAlexafffund
Kai Cui, Ken Bosnick, Rob Indoe, Marek Malac, Robert A. McLeod

Bibliographic record

VenueMicroscopy Research and Technique · 2017
Typearticle
Languageen
FieldMaterials Science
TopicElectron and X-Ray Spectroscopy Techniques
Canadian institutionsNational Research Council CanadaNational Institute for Nanotechnology
FundersNational Research Council Canada
KeywordsGrapheneMaterials scienceTransmission electron microscopyMonolayerNanotechnologySelected area diffractionMagnificationDiffractionOpticsPhysics

Abstract

fetched live from OpenAlex

Abstract Many new materials emerging are strictly two dimensional (2D), often only one or two monolayers thick. They include transition metal dichalcogenides, such as MoS 2 , and graphene. Graphene in particular appears to have many potential applications. Typically the crystalline film without contamination is of interest. Therefore, a reliable method is needed to routinely evaluate the quality of the synthesized samples. Here, we present one such candidate method that utilizes standard electron diffraction and low/medium magnification imaging in a rudimentary transmission electron microscope. The electron irradiation dose is very low thus reducing electron irradiation damage of the investigated samples. As an example, the method was applied to the evaluation of as‐grown graphene sample quality and a study on heating‐induced change in graphene. It can be used to evaluate the volume and areal ratio of crystalline to noncrystalline component. The method is amiable to automated film quality evaluation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.011
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.042
Threshold uncertainty score0.534

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0110.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0010.001
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.102
GPT teacher head0.479
Teacher spread0.377 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2017
Admission routes2
Has abstractyes

Explore more

Same venueMicroscopy Research and TechniqueSame topicElectron and X-Ray Spectroscopy TechniquesFrench-language works237,207