MétaCan
Menu
Back to cohort
Record W2598327500 · doi:10.1055/s-0037-1600452

Einfluss von Bildmatrix und Schichtdicke auf die subjektive Bildqualität in der HR-CT der Lunge: Untersuchung an einem Ultra-High-Resolution Ganzkörper-Prototyp-CT

2017· article· de· W2598327500 on OpenAlexaff
Patrik Rogalla, Mathias Prokop, Alain Blum, M Chen, Sonja Kandel, Christopher Farrell, Bernice E. Hoppel

Bibliographic record

VenueRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · 2017
Typearticle
Languagede
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsNuclear medicinePhysicsMedicine

Abstract

fetched live from OpenAlex

Zielsetzung: Ziel der Untersuchung war herauszufinden, ob eine Schichtdicke von 0.25 mm und 1024-Bildmatrix (1k) die Bildqualität in der HR-CT der Lunge verbessert. Material und Methodik: 59 Patienten erhielten ein Thorax-CT an einem 128-Zeilen Ganzkörper-Prototyp-CT (TSX-304R, Toshiba) mit: 0.25 mm Schichtdicke, 0.5 s Rotation, Dosismodulation (SD: 25 HU), 120 kV, AIDR-3D und Filter FC81. 6 Serien wurden rekonstruiert (Schichtdicke in mm/Bildmatrix): 0.25/1k, 0.25/512, 0.5/1k, 0.5/512, 2/1k und 2/512. Zwei Radiologen mit 21 und 4 Jahren Erfahrung beurteilten ohne Kenntnis der Parameter die Serien an einem 4K-Monitor (6:1-Aufteilung) mittels Forced-Ranking und freier Skala (1 = exzellent, 10 = schlecht) in den Kategorien: (K1) Darstellung von Bronchien, (K2) Gefäßen, (K3) Septen und Fissuren, (K4) Bildschärfe, (K5) Rausch-Textur, (K6) Artefakte und (K7) persönliche Präferrenz. Das Bildrauschen (SD in ROIs) wurde in der Aorta und in Luft auf allen 6 Serien gemessen, das DLP notiert. Die Statistik erfolgte mittels ANOVA für Haupt- und Interaktionseffekt und mittels Kendall-Koeffizient für Konkordanz (KKC). Ergebnisse: Haupt- und Interaktionseffekt der Bildmatrix und Schichtdicke waren in allen Kategorien signifikant bei p < 0.05, wobei die Bildmatrix generell einen stärken Effekt hatte als die Schichtdicke. Die 1k-Matrix wurde der 512-Matrix in K1-K3 vorgezogen, beide Befunder bevorzugten 0.25 mm gegenüber 0.5 und 2 mm (Forced Ranking). 2 mm mit 1k-Matrix wurde für Bildrauschen- und Artefakte¬unterdrückung bevorzugt, 0.25 mm mit 512-Matrix erhielt die schlechteste Bewertung. Auf der freien Skala erhielt 0.5 mm mit 1k (n.s.) die beste und 2 mm mit 512-Matrix die schlechteste Bewertung (p < 0.001). Der KKC lag bei 0,89 – 0,93 in K1-K3 und 0,66 – 0.83 in K4-K7. Das mittlere DLP war 377,9 mGy*cm. SD variierte zwischen 58.1 HU (0.25/1k) und 25.8 HU (2/512). Schlussfolgerungen: In der HR-CT der Lunge verbessert die 1024-Bildmatrix die Bildqualität im Vergleich zur 512-Matrix; 0.25 mm Schichtdicke wird überwiegend einer 0.5 mm Schichtdicke vorgezogen

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.005
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.036
GPT teacher head0.357
Teacher spread0.322 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden VerfahrenSame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207