MétaCan
Menu
Back to cohort
Record W2599849600 · doi:10.3171/2016.10.jns162083

Learning brain aneurysm microsurgical skills in a human placenta model: predictive validity

2017· article· en· W2599849600 on OpenAlex
Marcelo Magaldi Ribeiro de Oliveira, Carlos Eduardo Ferrarez, Taise Mosso Ramos, José Augusto Malheiros, Arthur Adolfo Nicolato, Carla Jorge Machado, Mauro Tostes Ferreira, Fellype Borges de Oliveira, C.F.P.M. de Sousa, Pollyana Helena Vieira Costa, Sebastião Gusmão, Giuseppe Lanzino, Rolando F. Del Maestro

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueJournal of neurosurgery · 2017
Typearticle
Languageen
FieldMedicine
TopicSurgical Simulation and Training
Canadian institutionsMcGill UniversityMontreal Neurological Institute and Hospital
FundersMontreal Neurological Institute and HospitalUniversidade Federal de Minas Gerais
KeywordsMedicineCadaverNeurosurgeryAneurysmCadaveric spasmMiddle cerebral arteryHuman placentaSurgeryPlacentaPregnancyInternal medicineIschemia

Abstract

fetched live from OpenAlex

OBJECTIVE Surgery for brain aneurysms is technically demanding. In recent years, the process to learn the technical skills necessary for these challenging procedures has been affected by a decrease in the number of surgical cases available and progressive restrictions on resident training hours. To overcome these limitations, surgical simulators such as cadaver heads and human placenta models have been developed. However, the effectiveness of these models in improving technical skills is unknown. This study assessed concurrent and predictive validity of brain aneurysm surgery simulation in a human placenta model compared with a "live" human brain cadaveric model. METHODS Two human cadaver heads and 30 human placentas were used. Twelve neurosurgeons participated in the concurrent validity part of this study, each operating on 1 human cadaver head aneurysm model and 1 human placenta model. Simulators were evaluated regarding their ability to simulate different surgical steps encountered during real surgery. The time to complete the entire aneurysm task in each simulator was analyzed. The predictive validity component of the study involved 9 neurosurgical residents divided into 3 groups to perform simulation exercises, each lasting 6 weeks. The training for the 3 groups consisted of educational video only (3 residents), human cadaver only (3 residents), and human placenta only (3 residents). All residents had equivalent microsurgical experience with superficial brain tumor surgery. After completing their practice training, residents in each of the 3 simulation groups performed surgery for an unruptured middle cerebral artery (MCA) aneurysm, and their performance was assessed by an experienced vascular neurosurgeon who watched the operative videos. RESULTS All human cadaver heads and human placentas were suitable to simulate brain aneurysm surgery. In the concurrent validity portion of the experiment, the placenta model required a longer time (p < 0.001) than cadavers to complete the task. The placenta model was considered more effective than the cadaver model in simulating sylvian fissure splitting, bipolar coagulation of oozing microvessels, and aneurysm neck and dome dissection. Both models were equally effective in simulating neck aneurysm clipping, while the cadaver model was considered superior for simulation of intraoperative rupture and for reproduction of real anatomy during simulation. In the predictive validity portion of the experiment, residents were evaluated for 4 tasks: sylvian fissure dissection, microvessel bipolar coagulation, aneurysm dissection, and aneurysm clipping. Residents trained in the human placenta simulator consistently had the highest overall performance scores when compared with those who had trained in the cadaver model and those who had simply watched operative videos (p < 0.001). CONCLUSIONS The human placenta biological simulator provides excellent simulation for some critical tasks of aneurysm surgery such as splitting of the sylvian fissure, dissection of the aneurysm neck and dome, and bipolar coagulation of surrounding microvessels. When performing surgery for an unruptured MCA aneurysm, residents who had trained in the human placenta model performed better than residents trained with other simulation scenarios/models. In this age of reduced exposure to aneurysm surgery and restrictions on resident working hours, the placenta model is a valid simulation for microneurosurgery with striking similarities with real surgery.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.011
Threshold uncertainty score0.553

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.059
GPT teacher head0.347
Teacher spread0.288 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it