MétaCan
Menu
Back to cohort
Record W2604610184 · doi:10.1177/1758573217701065

The effect of humeral polyethylene insert constraint on reverse shoulder arthroplasty biomechanics

2017· article· en· W2604610184 on OpenAlexaff
Irfan Abdulla, G. Daniel G. Langohr, Joshua W. Giles, James A. Johnson, George S. Athwal

Bibliographic record

VenueShoulder & Elbow · 2017
Typearticle
Languageen
FieldMedicine
TopicShoulder Injury and Treatment
Canadian institutionsSt Joseph's Health CareWestern University
Fundersnot available
KeywordsPolyethyleneRange of motionCadaveric spasmShouldersMedicineBiomechanicsDeltoid curveOrthodonticsShoulder jointDeltoid muscleArthroplastyJoint (building)Biomedical engineeringComposite materialSurgeryMaterials scienceAnatomyStructural engineeringEngineering

Abstract

fetched live from OpenAlex

Background There is little information on the effects of altering reverse shoulder arthroplasty (RSA) polyethylene constraint on joint load, load angle and deltoid force. The present biomechanical study aimed to investigate the effects of changing RSA polyethylene constraint on joint load, load angle, deltoid force and range of motion. Methods A custom RSA implant capable of measuring forces across the joint with varying polyethylene constraint was tested in six cadaveric shoulders. Standard-, low- and high-constraint (retentive) polyethylene liners were tested, and joint kinematics, loads and muscle forces were recorded. Results When polyethylene constraint was altered, joint load and load angle during active abduction were not affected significantly ( p > 0.19). Additionally, the force required by the deltoid for active abduction was not affected significantly by cup constraint ( p = 0.144). Interestingly, active abduction range of motion was also not affected significantly by changes in cup constraint ( p > 0.45). Conclusions Altering polyethylene cup constraint in RSA to enhance stability does not significantly alter resultant joint loads and deltoid forces. Surprisingly, terminal abduction range of motion was also not significantly different with varying cup constraint, indicating that terminal impingement may be tuberosity related rather than polyethylene.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.747
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0010.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.331
Teacher spread0.308 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueShoulder & ElbowSame topicShoulder Injury and TreatmentFrench-language works237,207