MétaCan
Menu
Back to cohort
Record W2604705116 · doi:10.2147/opth.s131607

A comparison of mesopic visual acuity and objective visual quality following cataract surgery with hydrophobic acrylic intraocular lenses

2017· article· en· W2604705116 on OpenAlexaff
George Beiko, Mišo Gostimir, Lila Haj-Ahmad

Bibliographic record

VenueClinical ophthalmology · 2017
Typearticle
Languageen
FieldMedicine
TopicOphthalmology and Visual Impairment Studies
Canadian institutionsMcGill UniversityUniversity of OttawaMcMaster UniversityUniversity of Toronto
FundersAmerican Society of Cataract and Refractive Surgery
KeywordsMesopic visionMedicineOphthalmologyIntraocular lensesVisual acuityCataract surgeryIntraocular lensOptometryRetinalPhotopic vision

Abstract

fetched live from OpenAlex

Purpose: To evaluate mesopic visual acuity and visual quality as measured by objective scatter index (OSI) in pseudophakic eyes with long-term follow-up after implantation of hydrophobic acrylic lenses made from two different lens materials. Setting: This study was carried out in a private clinic. Design: This study was an observational cohort study. Methods: This pilot study included 181 eyes of 136 patients who had undergone cataract surgery with implantation of monofocal hydrophobic acrylic intraocular lenses (IOLs), either Alcon AcrySof (82 eyes) or Abbott Medical Optics’ Tecnis (99 eyes). The monocular corrected distance visual acuity (CDVA) of the subjects was recorded under mesopic room illumination and OSI was measured by an optical quality analysis system using double-pass wavefront method. Results: Mean follow-up duration was 60.07±18.82 months. Eyes implanted with Tecnis IOLs had statistically significantly better mesopic CDVA (0.08±0.08) compared to those implanted with AcrySof IOLs (0.11±0.07) ( P =0.020). Mesopic CDVA of 20/25 or better was found in 79.8% of eyes in the Tecnis group compared to 62.2% of eyes in AcrySof group. Similarly, OSI was also found to be statistically significantly better for Tecnis IOLs compared to AcrySof IOL group (mean OSI, Tecnis: 1.65±0.92, AcrySof: 2.01±1.36; P =0.033). When glaucomatous eyes were excluded, OSI was still significantly better ( P =0.028) in the Tecnis IOL group. Conclusion: The eyes implanted with Tecnis IOLs showed better long-term optical performance in terms of both OSI and mesopic visual acuity in comparison to those with AcrySof IOLs. Keywords: objective scatter index, double pass, optical quality analysis system, optical performance of IOL

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.003
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0030.000
Bibliometrics0.0000.000
Science and technology studies0.0010.002
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.179
GPT teacher head0.543
Teacher spread0.364 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueClinical ophthalmologySame topicOphthalmology and Visual Impairment StudiesFrench-language works237,207