MétaCan
Menu
Back to cohort

Matched Comparison of Self-Expanding Transcatheter Heart Valves for the Treatment of Failed Aortic Surgical Bioprosthesis

2017· article· en· W2605453723 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueCirculation Cardiovascular Interventions · 2017
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsSt. Michael's Hospital
Fundersnot available
KeywordsMedicineCardiologyAortic valveHeart valveInternal medicinePropensity score matchingSurgeryStroke (engine)Hemodynamics

Abstract

fetched live from OpenAlex

Background— Transcatheter valve-in-valve implantation is an established therapy for high-risk patients with failed surgical aortic bioprosthesis. There are limited data comparing outcomes of valve-in-valve implantation using different transcatheter heart valves (THV). Methods and Results— Patients included in the Valve-in-Valve International Data registry (VIVID) and treated with self-expanding THV devices were analyzed using centralized core laboratory blinded to clinical events. St. Jude Medical Portico versus Medtronic CoreValve were compared in a 1:2 fashion after propensity score matching. A total of 162 patients, Portico- (n=54) and CoreValve- (n=108) based valve-in-valve procedures comprised the study population with no significant difference in baseline characteristics (age, 79±8.2 years; 60% women; mean STS [Society of Thoracic Surgery] score 8.1±5.5%). Postimplantation, CoreValve was associated with a larger effective orifice area (1.67 versus 1.31 cm 2 ; P =0.001), lower mean gradient (14±7.5 versus 17±7.5 mm Hg; P =0.02), and lower core laboratory–adjudicated moderate-to-severe aortic insufficiency (4.2% versus 13.7%; P =0.04), compared with Portico. Procedural complications including THV malpositioning, second THV requirement, or coronary obstruction were not significantly different between the 2 groups. Survival and stroke rates at 30 days were similar, but overall mortality at 1 year was higher among patients treated with Portico compared with CoreValve (22.6% versus 9.1%; P =0.03). Conclusions— In this first matched comparison of THVs for valve-in-valve implantations, Portico and CoreValve demonstrated differences in postprocedural hemodynamics and long-term clinical outcomes. Although this could be related to THV design characteristics, the impact of other procedural factors cannot be excluded and require further evaluation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (broad)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.045
Threshold uncertainty score0.989

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.021
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.072
GPT teacher head0.410
Teacher spread0.338 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it